FA125 firmware check 2.00D+

From GlueXWiki
Revision as of 09:29, 18 March 2016 by Njarvis (Talk | contribs)

Jump to: navigation, search
ver 2_00_D Discrepancies between CDC firmware output and emulation output, repeatfree=no repeated pairs
Run hits repeatfree hits diffs time q pedestal amplitude integral overflow count readout
10954 28658293 24179315 12394 61 0 1 12326 6 0 CDC
10956 87414131 73914777 145176 107559 275 4 37530 12672 0 CDC
10957 19196556 16340197 33186 24069 59 3 9086 2868 0 CDC & FDC

NB hits with repeated pairs are not necessarily an error, it was just simpler to exclude all of them

runs 10954 and 10956 time errors
Cdc run10954 dtt.png
Cdc run10956 dtt.png
Cdc run10954 dtch.png
Cdc run10956 dtch.png

Most of the discrepancies for run 10965 come from 6 channels where the firmware time = 1 + emulated time, they are not noise events.

run 10956 errors
Cdc run10956 rocslot.png
Cdc run10956 roc25.png
Cdc run10956 roc28.png



ver 2_00_E Discrepancies between CDC firmware output and emulation output, repeatfree=no repeated pairs
Run hits repeatfree hits diffs time q pedestal amplitude integral overflow count readout
10986 file 002 8058453 6875279 167 15 0 0 150 2 0 CDC & FDC
10986 files 002-005 32523087 27581269 688 72 0 0 612 4 0 CDC & FDC no cp - event 3779794 digihit 0
run 10986 file 002 errors
Cdc run10986 d amp.png
Cdc run10986 d time.png