Difference between revisions of "Feb 11, 2010 Readout"

From GlueXWiki
Jump to: navigation, search
(Tentative Agenda)
(Tentative Agenda)
Line 32: Line 32:
 
#* For reference: top = 2.525 cm, side =2.0 cm, bottom=2.4026 cm, cone to radius=1cm, Winston cone to radius=0.6cm (GlueX-doc-1077), efficiency=81%.
 
#* For reference: top = 2.525 cm, side =2.0 cm, bottom=2.4026 cm, cone to radius=1cm, Winston cone to radius=0.6cm (GlueX-doc-1077), efficiency=81%.
 
#* Preliminary results for collection efficiency for trapezoidal light guides with air gap:
 
#* Preliminary results for collection efficiency for trapezoidal light guides with air gap:
 +
#* Intput: top = 2.525 cm, side =2.0 cm, bottom=2.4026 cm, length = 8 cm
 +
#* output: 1.2cm x 1.2 cm square
 
#* Ratio of input/output areas = 0.29
 
#* Ratio of input/output areas = 0.29
#* top = 2.525 cm, side =2.0 cm, bottom=2.4026 cm, length = 8 cm, 1 mm lucite transition piece: efficiency = 87%.  
+
#* 1 mm lucite transition piece: efficiency = 87%.  
#* top = 2.525 cm, side =2.0 cm, bottom=2.4026 cm, length = 8 cm, 1 mm air gap, efficiency = 45%.
+
#* 1 mm air gap, efficiency = 45%.
 
# Geometry
 
# Geometry
 
# Discussion - MOU with USM
 
# Discussion - MOU with USM

Revision as of 11:51, 11 February 2010

Teleconference Time: 11:00 a.m. EST

  • ESNET and EVO session
  • Phone in CC F326 is 757-269-6337
  • Phone:
    • +1-800-377-8846 : US
    • +1-888-276-7715 : Canada
    • +1-302-709-8424 : International
    • then enter participant code: 77438230# (remember the "#"). Phone connection only upon request.

Items for followup from previous meeting

  1. Testing of new cal modules to measure light output and determine the range of phoelectrons expected.
  2. Sensitivity to Hadronic radiation: Stepan to provide information on damage to SiPMs during NH3 pol target run. (Stepan)
  3. Detailed task list of everything that needs to be accomplished to flush out the use of SiPMs. (Elton, Fernando, Carl, Eugene...)
  4. Input/Decisions needed to finalize Bcal readout requirements
    • Specify the normalization and dynamic range for the number of photons/GeV in showers
    • Decide on specific grouping for SiPM sums
    • Possibility of using air gap for SiPM coupling
    • Finalize shapes of "Winston guides"

Documents to Review

Tentative Agenda

  1. Announcements
  2. Review of Action Items
  3. Update - USM
    • First tests of SiPMs (Serguei)
  4. SiPM - update
  5. Light guides
    • For reference: top = 2.525 cm, side =2.0 cm, bottom=2.4026 cm, cone to radius=1cm, Winston cone to radius=0.6cm (GlueX-doc-1077), efficiency=81%.
    • Preliminary results for collection efficiency for trapezoidal light guides with air gap:
    • Intput: top = 2.525 cm, side =2.0 cm, bottom=2.4026 cm, length = 8 cm
    • output: 1.2cm x 1.2 cm square
    • Ratio of input/output areas = 0.29
    • 1 mm lucite transition piece: efficiency = 87%.
    • 1 mm air gap, efficiency = 45%.
  6. Geometry
  7. Discussion - MOU with USM

Minutes

Attending: