Feb 11, 2010 Readout
From GlueXWiki
Teleconference Time: 11:00 a.m. EST
- ESNET and EVO session
- Phone in CC F326 is 757-269-6337
- Phone:
- +1-800-377-8846 : US
- +1-888-276-7715 : Canada
- +1-302-709-8424 : International
- then enter participant code: 77438230# (remember the "#"). Phone connection only upon request.
Contents
Items for followup from previous meeting
- Testing of new cal modules to measure light output and determine the range of phoelectrons expected.
- Sensitivity to Hadronic radiation: Stepan to provide information on damage to SiPMs during NH3 pol target run. (Stepan)
- Detailed task list of everything that needs to be accomplished to flush out the use of SiPMs. (Elton, Fernando, Carl, Eugene...)
- Input/Decisions needed to finalize Bcal readout requirements (See also GlueX-doc-1373).
- Specify the normalization and dynamic range for the number of photons/GeV in showers
- Decide on specific grouping for SiPM sums
- Possibility of using air gap for SiPM coupling
- Finalize shapes of "Winston guides"
Documents to Review
Tentative Agenda
- Announcements
- Review of Action Items
- Update - USM
- First tests of SiPMs (Serguei)
- SiPM - update
- Light guides
- For reference: top = 2.525 cm, side =2.0 cm, bottom=2.4026 cm, cone to radius=1cm, Winston cone to radius=0.6cm (GlueX-doc-1077), efficiency=81%.
- Preliminary results for collection efficiency for trapezoidal light guides (inner outside top geometry) with air gap:
- Intput: top = 2.525 cm, side =2.0 cm, bottom=2.4026 cm, length = 8 cm
- output: 1.2cm x 1.2 cm square
- Ratio of input/output areas = 0.29
- 1 mm lucite transition piece: efficiency = 87%.
- 1 mm air gap, efficiency = 45%.
- Geometry
- Discussion - MOU with USM
Minutes
Attending: Fernando, Lubomir, Tim, Pedro, John, Eugene, Beni, Elton (JLab); Zisis, George, Andrei (UofR); Will (USM)
- Review of Action Items
- Baby Bcal has been received at USM. Serguei believes that it has been in quarantine because it was shipped in a bare wooden crate.
- USM should let us know how to treat shipping crates to avoid quarantine.
- Update - USM
- First tests of SiPMs (Serguei)
- SiPM - update
- Light guides
- For reference: top = 2.525 cm, side =2.0 cm, bottom=2.4026 cm, cone to radius=1cm, Winston cone to radius=0.6cm (GlueX-doc-1077), efficiency=81%.
- Preliminary results for collection efficiency for trapezoidal light guides (inner outside top geometry) with air gap:
- Intput: top = 2.525 cm, side =2.0 cm, bottom=2.4026 cm, length = 8 cm
- output: 1.2cm x 1.2 cm square
- Ratio of input/output areas = 0.29
- 1 mm lucite transition piece: efficiency = 87%.
- 1 mm air gap, efficiency = 45%.
- Geometry
- Discussion - MOU with USM