Feb 3, 2021 Calorimeter

From GlueXWiki
Revision as of 13:55, 3 February 2021 by Zisis (Talk | contribs)

Jump to: navigation, search

Meeting Day/Time: every other WEDNESDAY at 11:00 a.m. JLab time

  1. To join via a Web Browser, go to the page [1] https://bluejeans.com/907185247.
  2. To join via Polycom room system go to the IP Address: 199.48.152.152 (bjn.vc) and enter the meeting ID: 907185247.
  3. To join via phone, use one of the following numbers and the Conference ID: 907185247.
    • US or Canada: +1 408 740 7256 or
    • US or Canada: +1 888 240 2560
  4. Upon connection all microphones are automatically muted. To unmute your mike on a Polycom or equivalent unit, enter *4. Unmuting on a computer is trivial as there is a microphone button than can be clicked.
  5. More information on connecting to bluejeans is available.

Participant Direct Lines

  • JLab Phone in CC L207 is 757-269-7084 (usual room)
  • JLab Phone: in CC F326 is 757-269-6460
  • Phone in the Regina Video-conference Suite is 306-585-4204
  • Athens Phone: in Christina's office is 011-30-210-727-6947

References

  1. FCAL HDFCAL log book
  2. BCAL HDBCAL log book
  3. Calibrations: 2020 Data Production; RunPeriod-2019-11 Validation; Offline Monitoring Data Validation

Goals for Calorimetry Group

  1. Determine preliminary photon reconstruction efficiencies as a function of E, phi and theta in data and simulation with a point-to-point precision of at least 5%.
  2. Measure systematics of pi0/eta mass calibration as a function of detector position to a precision of at least 5 MeV.
  3. Demonstrate agreement of photon reconstruction efficiency and resolution between data and simulation as a function of E, phi and theta to within 5%.

Action Items

  1. Short term CALWG Items
  2. Long term items
  3. Calorimeter work packages

Tentative Agenda

  1. Announcements
  2. Run Preparations
    1. FCAL
    2. BCAL
  3. Calibration
    1. BCAL
      1. Z calibration (K Suresh) BCAL Z Update
      2. Peaking of Noise Showers at 220 cms in the BCAL
        1. For both the Photon Gun sample and the bggen sample, Run number 50715 was used. One sample was generated without any BKG (BKG=None) and another with (BKG=Random:recon-2018_08-ver02). Version XML : recon-2018_08-ver02_9.xml
  4. Monitoring
    1. BCAL LED
      1. Varun : SiPM dark rate study Sep 2020 update
    2. BCAL (offline)
    3. FCAL (offline)
      1. FCAL LED monitoring
      2. FCAL 2019-11 batch9
  5. Efficiency
  6. Reconstruction
    1. Tolga: Slight update to Photon Reconstruction checks for BCAL/Question
  7. Simulations
  8. Action Items
  9. Any other business

Minutes

Attending: Tolga, Karthik, Sean, Zisis, Mark, Rebecca, Varun, Jon, Churamani, Matt, Elton, Susan

  1. Announcements
    1. The CALWG meeting scheduled for Feb 17 will be cancelled, as the Feb Collaboration meeting starts that afternoon and has a heavy schedule, including calorimeter updates from PrimEx. The next CALWG meeting will thus be on March 3, perhaps jointly with PrimEx.
    2. Task Force reports at Collab Meeting: Sean will give a summary and technical reports will be written. One more photon recon meeting will be scheduled for next week.
    3. Matt mentioned that our collaboration has a draft charge for the March Review.
    4. Zisis reported that the COMCAL paper is being edited by the co-authors.
  2. Run Preparations
    1. FCAL: Mark will check on when the next 100 bases will come out for refurbishing. Firmware testing is ongoing. Hovanes and Nick will work on the integration within CSS. Jon et al will be consulted on the remote uploading procedure to the bases.
    2. BCAL: no report.
  3. Calibration
    1. BCAL
      1. Karthik reported on z-position correction to the non-linearity of the BCAL. Z calibration. Currently, we only have E-cor implemented, so he is picking up z-cor from this studies last year. As expected, the higher the Eg the z-coverage in the BCAL reduces to large z values. Use a single z bin to look at a correction. Karthik generated his own bggen sample instead of using the large-statistics one available for 2 reasons: a) the latter contains random noise (see issue in next bullet point below) and b) it does not contain the uncorrecte/raw energies in the trees, which he needs for this study. He used the pi0 skims and compared to Mark's gamma-gun MC. Sean recommended that the fits and background modelling be improved possibly by increasing the window around the pi0.
      2. Karthik shows a spike of random noise showers at 212 cm in the BCAL. Mark suggested that this could be due to how timing is assigned to these randoms and Sean agreed. Although the spike would not affect Karthik's studies (it can be cut out) it could be an issue for cross section extraction and it needs to be investigated further. Karthik will enter it as a GitHub issue so that Richard can have a look.
  4. Monitoring
    1. BCAL LED
      1. Varun : SiPM dark rate study Sep 2020 update
    2. BCAL (offline)
    3. FCAL (offline)
      1. FCAL LED monitoring
      2. FCAL 2019-11 batch9
  5. Efficiency
  6. Reconstruction
    1. Tolga: Slight update to Photon Reconstruction checks for BCAL/Question
  7. Simulations
  8. Action Items
  9. Any other business