#* the resolution of the Test Paddle is about 20% worse than the Reference paddle 21 (highest rate)
 
#* the resolution of the Test Paddle is about 20% worse than the Reference paddle 21 (highest rate)
 
#* going back to the basics by looking at wave forms and comparing to FPGA data uncovers that
 
#* going back to the basics by looking at wave forms and comparing to FPGA data uncovers that
#** algorithm is not adequate (due to high rates)!
+
#*# algorithm is not adequate (due to high rates)!
#** Pulse_Peak zero as error flag causes TOF walk correction to fail!
+
#*# Pulse_Peak zero as error flag causes TOF walk correction to fail!
 +
#** See logbook: https://logbooks.jlab.org/entry/3544404
 
# PMT testing
 
# PMT testing
 
# NIM Paper (Paul)
 
# NIM Paper (Paul)

Revision as of 16:23, 13 March 2018

GlueX Time-of-Flight Meeting
Wednesday, March 14, 2018
10:00 am EST
JLab: CEBAF Center, Room F226
BlueJeans Meeting number is 350 531 998

Agenda

  1. Announcements
  2. Review of minutes from the January 31 meeting
  3. Calibration Status
  4. Amplified Base Prototype (Beni)
    • the resolution of the Test Paddle is about 20% worse than the Reference paddle 21 (highest rate)
    • going back to the basics by looking at wave forms and comparing to FPGA data uncovers that
      1. algorithm is not adequate (due to high rates)!
      2. Pulse_Peak zero as error flag causes TOF walk correction to fail!
  5. PMT testing
  6. NIM Paper (Paul)
  7. Action Item Recap