HOWTO documentation

From GlueXWiki
Revision as of 08:10, 9 August 2006 by Davidl (Talk | contribs) (HOWTO Use the DAQ System)

Jump to: navigation, search

HOWTO Use the DAQ System

The DAQ system is generally kept running on the clon03 display(s) in the Hall-B counting house. Check first if it is there before restarting it so you don't accidentally kill a run in progress. Killing the current DAQ processes:

To kill the current DAQ processes, ssh into the halldrun account on clonxt2 and type "kill_daq". This will kill most of the DAQ processes, but not all (e.g. the mini-SQL server is not killed).


Starting the DAQ from scratch: To start the DAQ from scratch, ssh into the halldrun account on clonxt2 and type "start_daq". (Note that this will automatically run the kill_daq script first in order to remove any stray processes before starting fresh ones.) A number of new windows will open including: RunControl Server xterm (rcServer), Event Builder xterm (coda_eb), Event Recorder xterm (coda_er), CMLOG message browser, and RunControl GUI.

After the RunControl GUI window comes up:

  1. click on "Connect"
  2. click on "Configure"
  3. select the appropriate configuration and click "OK"
  4. click "Download"
  5. click "Start Run"
  6. click "End Run" whenever you are ready to end the run.

HOWTO Modify High Voltage

HOWTO Make a logbook Entry

HOWTO Access Online Histograms

HOWTO Move the BCAL

HOWTO Check the Beam

HOWTO Analyze Data Offline

HOWTO Use the Event Viewer

HOWTO Report ABUs