Inductance 2013

From GlueXWiki
Jump to: navigation, search

The inductance of subcoils is calculated using the voltages induced across each subcoils during ramp ups and ramp downs.

Data was taken during April 2013: Inductance_data.xlsx.

Inductance (H) 0 A 250 A 500 A 750 A 1000 A 1250 A 1350 A 1500 A
2A (VTT4) 1.535 1.527 1.505 1.471 1.423 1.363 1.335 1.289
2B (VTT5) 0.845 0.843 0.837 0.828 0.815 0.799 0.791 0.779
2C (VTT6) 0.912 0.909 0.905 0.899 0.892 0.883 0.879 0.873
2D (VTT7) 1.279 1.274 1.270 1.268 1.267 1.268 1.269 1.270
1AB (VTT8) 3.103 3.118 3.096 3.036 2.939 2.806 2.742 2.635
1C (VTT9) 0.583 0.585 0.582 0.576 0.565 0.550 0.543 0.531
1D (VTT10) 0.377 0.378 0.377 0.374 0.369 0.362 0.359 0.354
1E (VTT11) 1.333 1.333 1.329 1.321 1.310 1.296 1.290 1.279
1FG (VTT12) 2.490 2.488 2.482 2.473 2.459 2.441 2.433 2.420
3A (VTT13) 1.855 1.859 1.847 1.818 1.774 1.713 1.684 1.636
3BC (VTT14) 1.954 1.949 1.933 1.906 1.868 1.819 1.797 1.760
3D1 (VTT15) 0.258 0.256 0.253 0.250 0.245 0.239 0.237 0.233
3D2 (VTT16) 0.434 0.434 0.431 0.425 0.415 0.403 0.397 0.388
4AB (VTT17) 1.423 1.405 1.381 1.352 1.318 1.278 1.261 1.233
4C (VTT18) 5.419 5.318 5.196 5.051 4.885 4.696 4.615 4.486
4D (VTT19) 4.741 4.641 4.511 4.352 4.162 3.942 3.846 3.693
Total 28.541 28.316 27.935 27.399 26.707 25.860 25.477 24.857