= Action Items =
 
= Action Items =
 
[[Short term items]]:
 
[[Short term items]]:
# Send the location of a Wiki page to Matt, with information on the LED colors and voltages (Mark)
+
# <strike> Send the location of a Wiki page to Matt, with information on the LED colors and voltages (Mark) </strike> Matt confirmed that Mark had sent the information.
 
# Complete [https://halldweb.jlab.org/wiki-private/index.php/2018_Work_Packages#Calorimetry Calorimeter work packages]
 
# Complete [https://halldweb.jlab.org/wiki-private/index.php/2018_Work_Packages#Calorimetry Calorimeter work packages]
  
Line 60: Line 60:
  
 
= Minutes =
 
= Minutes =
''Attending:
+
''Attending: Elton, Mark, Colin (JLab); Will (CMU); George, Christina (Athens); Jon, Matt (IU); Zisis, Ahmed, Karthik, Varun, James, Gabriel Dhillon (Regina): Sean (FSU); Tolga (FIU)
 +
 
 +
# Announcements
 +
## Jon has completed his Ph.D. and has taken a post doc position at Regina (stationed at JLab) starting in mid Aug. Congratulations!
 +
# Run Updates
 +
## FCAL
 +
##* Sasha has taken some FADC data with FCAL LEDs to check new firmware that should solve the 4 ns shifts.
 +
##* The CPP experiment is considering installing the muon detector partially into the dark box. This is make the space inside the darkroom very tight to work (~ 20") but would only be used during the 1-month CPP run. A mockup of cardboard and/or other material will be placed in the dark room to evaluate the practicality of such an option with respect to servicing the FCAL.
 +
## BCAL
 +
##* Chillers are being serviced, filters changed, as routine maintenance.
 +
# Calibrations
 +
## [https://halldweb.jlab.org/wiki/images/f/f8/SiPM_saturation.pdf] SIPM Saturation(Dhillon)
 +
##* The unexpected small value of SiPM saturation needed for the BCAL calibration is being investigated with direct measurements of the hardware. Dhillon and Breanna were at JLab for 3 weeks and got a test setup working and took considerable data.
 +
##* Setup is in the EEL, using a dark box with a laser in Fernando's lab
 +
##* Laser light was adjusted by inserting filters of known attenuation into the laser beam (followed a by a diffuser)
 +
##* Integral/peak ~ 7, where we find a value of about 12.8 in physics data. The difference is likely due to the increased width of the physics pulses due to reflections in the BCAL.
 +
##* The light intensity scale was scaled to reproduce the measured peak value at low intensity. The saturation is measured relative to this.
 +
##* Preliminary saturation curves were shown. Other data sets will be analyzed and a report completed by the end of the summer.
 +
## [https://halldweb.jlab.org/doc-private/DocDB/ShowDocument?docid=4118 GlueX-doc-4118] SiPM saturation using laser knob calibration (Elton)
 +
##* After Dhillon and Breanna returned to Regina, we borrowed a calibrated photodiode from Carl Zorn to calibrate the photon flux.
 +
##* We also observed that the intensity of the laser increases as the laser is warming up and opening and closing the dark box to insert filters leads to important systematics.
 +
##* We calibrated the laser intensity knob with the diode and used this to do an intensity scan using the laser knob that did not require opening and closing the box.
 +
##* Preliminary saturation curves were presented.
 +
# Monitoring
 +
# Simulations
 +
## [https://halldweb.jlab.org/doc-private/DocDB/ShowDocument?docid=4116 GlueX-doc-4116] CWP Item #10 Update: Particle Guns dT separation (Tolga)
 +
## [https://halldweb.jlab.org/doc-private/DocDB/ShowDocument?docid=4115 GlueX-doc-4115] Costhe Efficiencies Update (Elton)
 +
# BCAL Deep Learning
 +
## First Update on BCAL- Deep Learning.[[File:BCAL_DL_update_11_july.pdf]]
 +
# NIM articles
 +
# Any other business

Revision as of 17:02, 11 July 2019

Meeting Time: 11:00 a.m.

  1. To join via a Web Browser, go to the page [1] https://bluejeans.com/907185247.
  2. To join via Polycom room system go to the IP Address: 199.48.152.152 (bjn.vc) and enter the meeting ID: 907185247.
  3. To join via phone, use one of the following numbers and the Conference ID: 907185247.
    • US or Canada: +1 408 740 7256 or
    • US or Canada: +1 888 240 2560
  4. Upon connection all microphones are automatically muted. To unmute your mike on a Polycom or equivalent unit, enter *4. Unmuting on a computer is trivial as there is a microphone button than can be clicked.
  5. More information on connecting to bluejeans is available.

Participant Direct Lines

  • JLab Phone in CC L207 is 757-269-7084 (usual room)
  • JLab Phone: in CC F326 is 757-269-6460
  • Phone in the Regina Video-conference Suite is 306-585-4204
  • Athens Phone: in Christina's office is 011-30-210-727-6947

References

  1. FCAL HDFCAL log book
  2. BCAL HDBCAL log book

Goals for Calorimetry Group

  1. Determine preliminary photon reconstruction efficiencies as a function of E, phi and theta in data and simulation with a point-to-point precision of at least 5%.
  2. Measure systematics of pi0/eta mass calibration as a function of detector position to a precision of at east 5 MeV.
  3. Demonstrate agreement of photon reconstruction efficiency and resolution between data and simulation as a function of E, phi and theta to within 5%.

Action Items

Short term items:

  1. Send the location of a Wiki page to Matt, with information on the LED colors and voltages (Mark) Matt confirmed that Mark had sent the information.
  2. Complete Calorimeter work packages

Long term items:

  1. From Mike's work: -cos(phi) type dependence in the data and a phi dependence at the downstream end of the bcal. See Sep 21, 2017 Calorimeter Meeting.
  2. FCAL: It has been noticed that the pi0 mass shifts when the LED pulser runs at high rate. This is still not understood. See Log Entry 3595928 and references. Several runs have been taken in raw mode. These runs exhibit the shift in pi0 mass with LED running at 1 kHz. There is a need to analyze these to try to determine the cause:
    1. 50634 - FCAL Green LED: 1kHz, 29 V, Livetime is 9%, 1.7 M events
    2. 50635 - FCAL Violet LED: 1kHz, 22 V, Livetime is 9%, 1.4 M events
    3. 50636 - FCAL Blue LED: 1kHz, 15 V, Livetime is 9%, 1.5 M events

Tentative Agenda

  1. Announcements
  2. Action Items
  1. Run Updates
    1. FCAL
    2. BCAL
  2. Calibrations
    1. GlueX-doc-4118 SiPM saturation using laser knob calibration (Elton)
    2. [2] SIPM Saturation(Dhillon)
  3. Monitoring
  4. Simulations
    1. GlueX-doc-4116 CWP Item #10 Update: Particle Guns dT separation (Tolga)
    2. GlueX-doc-4115 Costhe Efficiencies Update (Elton)
  5. BCAL Deep Learning
    1. First Update on BCAL- Deep Learning.File:BCAL DL update 11 july.pdf
  6. NIM articles
  7. Any other business

Minutes

Attending: Elton, Mark, Colin (JLab); Will (CMU); George, Christina (Athens); Jon, Matt (IU); Zisis, Ahmed, Karthik, Varun, James, Gabriel Dhillon (Regina): Sean (FSU); Tolga (FIU)

  1. Announcements
    1. Jon has completed his Ph.D. and has taken a post doc position at Regina (stationed at JLab) starting in mid Aug. Congratulations!
  2. Run Updates
    1. FCAL
      • Sasha has taken some FADC data with FCAL LEDs to check new firmware that should solve the 4 ns shifts.
      • The CPP experiment is considering installing the muon detector partially into the dark box. This is make the space inside the darkroom very tight to work (~ 20") but would only be used during the 1-month CPP run. A mockup of cardboard and/or other material will be placed in the dark room to evaluate the practicality of such an option with respect to servicing the FCAL.
    2. BCAL
      • Chillers are being serviced, filters changed, as routine maintenance.
  3. Calibrations
    1. [3] SIPM Saturation(Dhillon)
      • The unexpected small value of SiPM saturation needed for the BCAL calibration is being investigated with direct measurements of the hardware. Dhillon and Breanna were at JLab for 3 weeks and got a test setup working and took considerable data.
      • Setup is in the EEL, using a dark box with a laser in Fernando's lab
      • Laser light was adjusted by inserting filters of known attenuation into the laser beam (followed a by a diffuser)
      • Integral/peak ~ 7, where we find a value of about 12.8 in physics data. The difference is likely due to the increased width of the physics pulses due to reflections in the BCAL.
      • The light intensity scale was scaled to reproduce the measured peak value at low intensity. The saturation is measured relative to this.
      • Preliminary saturation curves were shown. Other data sets will be analyzed and a report completed by the end of the summer.
    2. GlueX-doc-4118 SiPM saturation using laser knob calibration (Elton)
      • After Dhillon and Breanna returned to Regina, we borrowed a calibrated photodiode from Carl Zorn to calibrate the photon flux.
      • We also observed that the intensity of the laser increases as the laser is warming up and opening and closing the dark box to insert filters leads to important systematics.
      • We calibrated the laser intensity knob with the diode and used this to do an intensity scan using the laser knob that did not require opening and closing the box.
      • Preliminary saturation curves were presented.
  4. Monitoring
  5. Simulations
    1. GlueX-doc-4116 CWP Item #10 Update: Particle Guns dT separation (Tolga)
    2. GlueX-doc-4115 Costhe Efficiencies Update (Elton)
  6. BCAL Deep Learning
    1. First Update on BCAL- Deep Learning.File:BCAL DL update 11 july.pdf
  7. NIM articles
  8. Any other business