#* Sasha will start working on the trigger and will turn on selective parts of the Fcal and Bcal to support the studies.
 
# FCAL Update
 
# FCAL Update
 +
## General updates (Matt)
 +
##* Adesh has moved to Florida and there are several loose ends that need to be picked up
 +
##* Repeating calibration with correct block size
 +
##* Use photons with a narrow energy range
 +
##* Understand the puzzle related to the fact that the measured Fcal energy does not improve with energy. This could in part be due to poor background representation.
 +
##* Add dead channels into the MC. Jared is using the LED data to investigate problematic channels
 +
## Timing studies
 +
##* Joe is using the LED data to check time walk, which should be absent in the FADC data. Investigate with LED data with varying intensity
 +
##* Matt is using the sample of clean omegas to check various timing aspects. Looking at timing between particles and the event time. Investigate the optimal time for a cluster. For example the energy average time might be better than the time of the largest block, which is currently being used.
 
## [[media:Fcal_shower_classification.pdf|Classifying FCAL Showers (Rebecca Barsotti)]]
 
## [[media:Fcal_shower_classification.pdf|Classifying FCAL Showers (Rebecca Barsotti)]]
 
# BCAL update
 
# BCAL update

Revision as of 12:15, 13 July 2017

Video Conferencing Information

Meeting Time: 11:00 a.m.

  1. To join via a Web Browser, go to the page [1] https://bluejeans.com/907185247.
  2. To join via Polycom room system go to the IP Address: 199.48.152.152 (bjn.vc) and enter the meeting ID: 907185247.
  3. To join via phone, use one of the following numbers and the Conference ID: 907185247.
    • US or Canada: +1 408 740 7256 or
    • US or Canada: +1 888 240 2560
  4. Upon connection all microphones are automatically muted. To unmute your mike on a Polycom or equivalent unit, enter *4. Unmuting on a computer is trivial as there is a microphone button than can be clicked.
  5. More information on connecting to bluejeans is available.

Participant Direct Lines

  • JLab Phone in CC L207 is 757-269-7084 (usual room)
  • JLab Phone: in CC F326 is 757-269-6460
  • Phone in the Regina Video-conference Suite is 306-585-4204
  • Athens Phone: in Christina's office is 011-30-210-727-6947

Action Items

  1. Decide on procedure to calibrate 4ns offsets during the next run.
  2. Check in the code, including scripts, that is used for recent calibrations into git (BCAL: Mark, FCAL:Adesh)

References

  1. FCAL HDFCAL log book
  2. BCAL HDBCAL log book

Tentative Agenda

  1. Announcements
  2. Action Items
  3. Activities during the down
  4. FCAL Update
    1. Classifying FCAL Showers (Rebecca Barsotti)
  5. BCAL update
  6. Calibrations
  7. Reconstruction and Simulation
    1. 2017 mcsmear Workplan
  8. NIM articles
  9. Any other business

Minutes

Attendees: Elton, Mark (JLab); Zisis, Ahmed (UofR); Sean (NW); Christina, George (Athens); Matt, Joe, Rebecca Barsotti (IU)

  1. Announcements
    • Accelerator expects startup on Sep 28 and start to deliver beam to experimental halls during the first week of October.
  2. Action Items
  3. Activities during the down
    • Sasha will start working on the trigger and will turn on selective parts of the Fcal and Bcal to support the studies.
  4. FCAL Update
    1. General updates (Matt)
      • Adesh has moved to Florida and there are several loose ends that need to be picked up
      • Repeating calibration with correct block size
      • Use photons with a narrow energy range
      • Understand the puzzle related to the fact that the measured Fcal energy does not improve with energy. This could in part be due to poor background representation.
      • Add dead channels into the MC. Jared is using the LED data to investigate problematic channels
    2. Timing studies
      • Joe is using the LED data to check time walk, which should be absent in the FADC data. Investigate with LED data with varying intensity
      • Matt is using the sample of clean omegas to check various timing aspects. Looking at timing between particles and the event time. Investigate the optimal time for a cluster. For example the energy average time might be better than the time of the largest block, which is currently being used.
    3. Classifying FCAL Showers (Rebecca Barsotti)
  5. BCAL update
  6. Calibrations
  7. Reconstruction and Simulation
    1. 2017 mcsmear Workplan
  8. NIM articles
  9. Any other business