Difference between revisions of "July 18, 2008 Software"

From GlueXWiki
Jump to: navigation, search
Line 36: Line 36:
 
Attendees: David L. (chair), Mark I., Alke A., Elton S., Simon T., Beni Z., Jim S., Alex S.
 
Attendees: David L. (chair), Mark I., Alke A., Elton S., Simon T., Beni Z., Jim S., Alex S.
  
EVI: Curtis M.
+
EVO: Curtis M.
 +
 
 +
===Updates on Geometry specified in XML===
 +
Beni gave a summary of some recent changes he's made to the XML-based simulation geometry for GlueX (see his figures above). These included:
 +
 
 +
* Re-routing the FDC cables upstream instead of downstream
 +
* Adding an inner aluminum plate to the BCAL
 +
* Reconfiguring the BCAL for the alternate readout scheme (3x3 for the inner section instead of 6x4)
 +
* Rotation of CDC layers wrt one another to break up alignments
 +
* Close packing CDC layers to improve LR resolution and fit more layers into the over CDC volume
 +
 
 +
The BCAL and CDC changes are not all committed to the repository just yet. They have been distributed
 +
to the Regina/IU folks and CMU/JLab folks respectively to run M.C. tests on first.
 +
 
 +
Beni has also made a lot of use of the ROOT tools based on the output of the hdds-root program. One "gotcha" encountered though is that ROOT will plot all volumes even if they exist in such a way that particles tracked by GEANT could never enter them. This is due to overlapping volumes or daughter values extending outside their parent.
 +
 
 +
There was also an issue with polygons used to define the FDC cables needing to be defined in ascending-z order.
 +
 
 +
It was noted that some simulations have already been performed by Regina/IU with the 4x6 readout geometry and that new ones were being planned with the 3x3 geometry. There was a question however as to whether the FDC cabling was "visible" to geant in the initial MC study of the BCAL so this should be verified before comparisons are made to the alternate readout geometry results.
 +
 
  
  

Revision as of 16:59, 22 July 2008

Agenda

  1. Review minutes from July 3, 2008 Software meeting
  2. Updates on Geometry specified in XML (Beni Z.)
    • FDC route cables upstream
      Fdc cableupstream.jpg
    • BCAL 6x4 readout with aluminum plate
      Bcal 6x4.jpg
    • BCAL 3x3 readout
      Bcal 3x3.jpg
    • CDC rotate layers
      Cdc layers shifted.jpg
    • CDC closed packing of axial layers zoom
      Cdc closedpacking zoom.jpg
    • CDC closed packing of axial layers leaves space for 3 more layers (stereo)
      Cdc closedpacking.jpg
  3. Coding Conventions (all)
  4. Action Items

Participating

Location

The meeting will be at 1:00pm in Cebaf Center F326.

Telephone

To connect by telephone: 1.) dial:

800-377-8846 : US
888-276-7715 : Canada
302-709-8424 : International

2.) enter participant code: 39527048# (remember the "#")

Video Conferencing

We will attempt an EVO connection for this meeting. We have a reasonable expectation that this will work.


Minutes

Attendees: David L. (chair), Mark I., Alke A., Elton S., Simon T., Beni Z., Jim S., Alex S.

EVO: Curtis M.

Updates on Geometry specified in XML

Beni gave a summary of some recent changes he's made to the XML-based simulation geometry for GlueX (see his figures above). These included:

  • Re-routing the FDC cables upstream instead of downstream
  • Adding an inner aluminum plate to the BCAL
  • Reconfiguring the BCAL for the alternate readout scheme (3x3 for the inner section instead of 6x4)
  • Rotation of CDC layers wrt one another to break up alignments
  • Close packing CDC layers to improve LR resolution and fit more layers into the over CDC volume

The BCAL and CDC changes are not all committed to the repository just yet. They have been distributed to the Regina/IU folks and CMU/JLab folks respectively to run M.C. tests on first.

Beni has also made a lot of use of the ROOT tools based on the output of the hdds-root program. One "gotcha" encountered though is that ROOT will plot all volumes even if they exist in such a way that particles tracked by GEANT could never enter them. This is due to overlapping volumes or daughter values extending outside their parent.

There was also an issue with polygons used to define the FDC cables needing to be defined in ascending-z order.

It was noted that some simulations have already been performed by Regina/IU with the 4x6 readout geometry and that new ones were being planned with the 3x3 geometry. There was a question however as to whether the FDC cabling was "visible" to geant in the initial MC study of the BCAL so this should be verified before comparisons are made to the alternate readout geometry results.


Action items

Next Meeting

TBD