Difference between revisions of "Jun 5, 2009 Readout"
From GlueXWiki
(→Minutes) |
|||
Line 23: | Line 23: | ||
##* Report at [[Apr 2, 2009 Calorimetry]] Meeting | ##* Report at [[Apr 2, 2009 Calorimetry]] Meeting | ||
##* See also [http://argus.phys.uregina.ca/cgi-bin/private/DocDB/ShowDocument?docid=849 GlueX-doc-849] and [http://argus.phys.uregina.ca/cgi-bin/private/DocDB/ShowDocument?docid=1231 GlueX-doc-1231] for reconstruction references. | ##* See also [http://argus.phys.uregina.ca/cgi-bin/private/DocDB/ShowDocument?docid=849 GlueX-doc-849] and [http://argus.phys.uregina.ca/cgi-bin/private/DocDB/ShowDocument?docid=1231 GlueX-doc-1231] for reconstruction references. | ||
+ | ## Algorithm | ||
+ | ##* Requires hits on both ends of the Bcal | ||
+ | ##* Assumes that hits on only one side of the Bdal can be added in a second reconstruction pass | ||
+ | ##* Finds clusters at the same radius (and delta phi). For showers in the same module, it attempts to separate them out along the beam line (z). | ||
+ | ##* Eugene: for timing, hits will be discriminated with higher threshold. | ||
+ | ##* Note: The GEANT threshold is currently very low, about 1 MeV in the Pb/fiber matrix. This way, different thresholds can be applied at the analysis stage. | ||
# What needs to be studied? | # What needs to be studied? | ||
# Who/how to best accomplish this list. | # Who/how to best accomplish this list. | ||
+ | #* Add model for FM light guides to GEANT (Beni and Sasha) | ||
+ | #* Eugene: At the analysis we need to add a discriminator threshold, as well as realistic minimum requirements in the cells if timing is to be used | ||
+ | #* Cerenkov background in light guides (Sasha) | ||
+ | #* Once geometry with light guides is in, IU can redo acceptance studies of gap between Fcal and Bcal. |
Revision as of 18:02, 5 June 2009
Teleconference Time: 1:30 p.m. EST
- ESNET session
Tentative Agenda
The purpose of the meeting was to review what MC simulations were needed to support the decision on the Bcal readout.
- Status (Matt). What exists and what has been studied.
- What needs to be studied?
- Who/how to best accomplish this list.
Minutes
Attending: Elton, David, Beni, Eugene, Sasha, Matt
- Status (Matt). What exists and what has been studied.
- Digitization with SiPMs including realistic parameters for detector, thresholds to set occupancy. The simulation of timing is not very realistic.
- Reconstruction
- Based on KLOE algorithm
- Finds showers and reconstructs them, perhaps not optimized. Downstream programs exist to reconstruct pi0s.
- Beni implemented the geometry to do the 3x3 inner FM PMT option. This is for the straight light guides, no implementation of impact of light guides on reconstruction.
- Documentation
- Report at Apr 2, 2009 Calorimetry Meeting
- See also GlueX-doc-849 and GlueX-doc-1231 for reconstruction references.
- Algorithm
- Requires hits on both ends of the Bcal
- Assumes that hits on only one side of the Bdal can be added in a second reconstruction pass
- Finds clusters at the same radius (and delta phi). For showers in the same module, it attempts to separate them out along the beam line (z).
- Eugene: for timing, hits will be discriminated with higher threshold.
- Note: The GEANT threshold is currently very low, about 1 MeV in the Pb/fiber matrix. This way, different thresholds can be applied at the analysis stage.
- What needs to be studied?
- Who/how to best accomplish this list.
- Add model for FM light guides to GEANT (Beni and Sasha)
- Eugene: At the analysis we need to add a discriminator threshold, as well as realistic minimum requirements in the cells if timing is to be used
- Cerenkov background in light guides (Sasha)
- Once geometry with light guides is in, IU can redo acceptance studies of gap between Fcal and Bcal.