Difference between revisions of "Level-3 Trigger Strategy"

From GlueXWiki
Jump to: navigation, search
Line 1: Line 1:
 
__TOC__
 
__TOC__
  
This page will collect the current planned running times/intensities for GlueX and the expected event rates.  Based on this a set of requirements can be collected for the Level-3 trigger to document the strategy for implementation
+
This page will collect the currently planned running times/intensities for GlueX and the expected event rates.  A set of requirements for the Level-3 trigger can be collected based on this information to document the design and implementation strategy.
  
== Approved GlueX Running Time (from [http://argus.phys.uregina.ca/cgi-bin/private/DocDB/ShowDocument?docid=2201 PAC 40 Proposal])==
+
== Planned GlueX Running (from [http://argus.phys.uregina.ca/cgi-bin/private/DocDB/ShowDocument?docid=2201 PAC 40 Proposal])==
  
 
{| class="wikitable"
 
{| class="wikitable"
 
|-
 
|-
!  !! Phase I !! Phase II !! Phase III !! Phase IV  
+
!  !! Phase I !! Phase II !! Phase III !! Phase IV !! Maximum Intensity
 
|-
 
|-
| PAC days || 30 || 30 || 60 || 200
+
| Approved PAC days || 30 || 30 || 60 || 200 || X
 
|-
 
|-
| Minimum electron energy (GeV) || 10 || 11 || 12 || 12
+
| Minimum electron energy (GeV) || 10 || 11 || 12 || 12 || 12
 
|-
 
|-
| Photon flux in coherent peak (photon/s) || <math>10^6</math> || <math>10^7</math> || <math>10^7</math> || <math>5 x 10^7</math>
+
| Photon flux in coherent peak (photon/s) || <math>10^6</math> || <math>10^7</math> || <math>10^7</math> || <math>5 x 10^7</math> || <math>10^8</math>
 
|-
 
|-
| Level-1 trigger rate (kHz) || 2 || 20 || 20 || 200
+
| Expected total hadronic event rate (kHz) || ?? || ?? || 36 || 180 || 360
 +
|-
 +
| Expected hadronic event rate in coherent peak (kHz) || ?? || ?? || 0.8 || 8 || 16
 +
|-
 +
| Level-1 trigger rate (kHz) || 2 || 20 || 20 || 100 || 200
 
|}
 
|}

Revision as of 09:34, 19 August 2013

This page will collect the currently planned running times/intensities for GlueX and the expected event rates. A set of requirements for the Level-3 trigger can be collected based on this information to document the design and implementation strategy.

Planned GlueX Running (from PAC 40 Proposal)

Phase I Phase II Phase III Phase IV Maximum Intensity
Approved PAC days 30 30 60 200 X
Minimum electron energy (GeV) 10 11 12 12 12
Photon flux in coherent peak (photon/s) 10^{6} 10^{7} 10^{7} 5x10^{7} 10^{8}
Expected total hadronic event rate (kHz)  ??  ?? 36 180 360
Expected hadronic event rate in coherent peak (kHz)  ??  ?? 0.8 8 16
Level-1 trigger rate (kHz) 2 20 20 100 200