Difference between revisions of "List of FCAL Beamtest Electronics"

From GlueXWiki
Jump to: navigation, search
(Summary of necessary electronics and spares available at IU)
 
(5 intermediate revisions by the same user not shown)
Line 1: Line 1:
== List of electronics to be used, from left to right (links are to Fermilab) ==
+
== List of electronics to be used (links are to Fermilab) ==
 
[[File:Electronics_diagram.jpg|750px|thumb|left|Picture of electronics setup.]]
 
[[File:Electronics_diagram.jpg|750px|thumb|left|Picture of electronics setup.]]
 
<br style="clear:both;"/>
 
<br style="clear:both;"/>
Line 5: Line 5:
 
* [http://www-esd.fnal.gov/esd/catalog/main/bertan/320.pdf Bertan 313B High Voltage Supply (pdf)] - high voltage supply for remote trigger
 
* [http://www-esd.fnal.gov/esd/catalog/main/bertan/320.pdf Bertan 313B High Voltage Supply (pdf)] - high voltage supply for remote trigger
 
* [http://www.fnal.gov/projects/ckm/jlab/726-spec.htm Phillips 726 ECL/NIM/TTL Translator] - final translation of NIM signal to TTL for input into fADC
 
* [http://www.fnal.gov/projects/ckm/jlab/726-spec.htm Phillips 726 ECL/NIM/TTL Translator] - final translation of NIM signal to TTL for input into fADC
* [http://www-esd.fnal.gov/esd/catalog/main/lcrynim/465-spec.htm LeCroy 465 Triple 4-Fold Logic Unit (I)] - AND of remote trigger and 3 horizontal signals
+
* [http://www-esd.fnal.gov/esd/catalog/main/lcrynim/429a-spec.htm LeCroy 429A Logic Fan-In/Out (II)] - Use top channel for OR of 4 VETO counter signals. This will then go into the VETO signal in the LeCroy 365AL Dual 4-Fold Logic. The middle and bottom channels should be used as the 3-way OR of the horizontal and vertical trigger signals, respectively. The front panel switch should be set to "'''4x4'''" so that the 3 channels are all independent of each other. Note that for simplicity of electronics, we take the OR of the 4 outside VETO counters, and input them as the VETO into the final trigger signal.
* [http://www-esd.fnal.gov/esd/catalog/main/lcrynim/465-spec.htm LeCroy 465 Triple 4-Fold Logic Unit (II)] - AND of remote trigger and 3 vertical signals
+
* [http://www-esd.fnal.gov/esd/catalog/main/lcrynim/621l-spec.htm LeCroy 621L Quad Discriminator] - discriminator for 4 outside VETO counters
* [http://www-esd.fnal.gov/esd/catalog/main/psnim/755-spec.htm Phillips 755 Quad 4-Fold Logic Unit] - AND of remote trigger and 4 outside VETO counters
+
<!-- We will not use LeCroy 825E Discriminators -->
* [http://www-esd.fnal.gov/esd/catalog/main/lcrynim/429a-spec.htm LeCroy 429A Logic Fan-In/Out (I)] - FAN-OUT of remote trigger into 10 channels for coincidence with trigger modules. The front panel switch should be set to "'''1x16'''" so that the output of the discriminated remote trigger is fanned out into all 16 OUTs.
+
<!-- * LeCroy 825E Risetime-Compensated Discriminator (I) - discriminator for 3 horizontal trigger signals -->
 +
<!-- * LeCroy 825E Risetime-Compensated Discriminator (II) - discriminator for 3 vertical trigger signals -->
 +
* [http://www.fnal.gov/projects/ckm/jlab/623b-spec.htm LeCroy 623B Octal Updating Discriminator] - discriminator for 6 inside signals and 1 remote trigger
 
* [http://www.fnal.gov/projects/ckm/jlab/364al-spec.htm LeCroy 365AL Dual 4-Fold Logic] - Final AND to output trigger signal. Pins should be set to OFF for channels "C" and "D", and the coincidence level should be set at "'''1'''". The inputs into the AND will be
 
* [http://www.fnal.gov/projects/ckm/jlab/364al-spec.htm LeCroy 365AL Dual 4-Fold Logic] - Final AND to output trigger signal. Pins should be set to OFF for channels "C" and "D", and the coincidence level should be set at "'''1'''". The inputs into the AND will be
 
** the 3-way OR signal of the horizontal bars
 
** the 3-way OR signal of the horizontal bars
 
** the 3-way OR signal of the vertical bars
 
** the 3-way OR signal of the vertical bars
 
** the 4-way OR signal of the VETO counters should be put in VETO
 
** the 4-way OR signal of the VETO counters should be put in VETO
* LeCroy 825E Risetime-Compensated Discriminator (I) - discriminator for 3 horizontal trigger signals
+
* [http://www-esd.fnal.gov/esd/catalog/main/lcrynim/429a-spec.htm LeCroy 429A Logic Fan-In/Out (I)] - FAN-OUT of remote trigger into 10 channels for coincidence with trigger modules. The front panel switch should be set to "'''1x16'''" so that the output of the discriminated remote trigger is fanned out into all 16 OUTs.
* LeCroy 825E Risetime-Compensated Discriminator (II) - discriminator for 3 vertical trigger signals
+
* [http://www-esd.fnal.gov/esd/catalog/main/psnim/755-spec.htm Phillips 755 Quad 4-Fold Logic Unit] - AND of remote trigger and 4 outside VETO counters
* [http://www-esd.fnal.gov/esd/catalog/main/lcrynim/621l-spec.htm LeCroy 621L Quad Discriminator] - discriminator for 4 outside VETO counters
+
* [http://www-esd.fnal.gov/esd/catalog/main/lcrynim/465-spec.htm LeCroy 465 Triple 4-Fold Logic Unit (I)] - AND of remote trigger and 3 horizontal signals
* [http://www-esd.fnal.gov/esd/catalog/main/lcrynim/429a-spec.htm LeCroy 429A Logic Fan-In/Out (II)] - Use top channel for OR of 4 VETO counter signals. This will then go into the VETO signal in the LeCroy 365AL Dual 4-Fold Logic. The middle and bottom channels should be used as the 3-way OR of the horizontal and vertical trigger signals, respectively. The front panel switch should be set to "'''4x4'''" so that the 3 channels are all independent of each other. Note that for simplicity of electronics, we take the OR of the 4 outside VETO counters, and input them as the VETO into the final trigger signal.
+
* [http://www-esd.fnal.gov/esd/catalog/main/lcrynim/465-spec.htm LeCroy 465 Triple 4-Fold Logic Unit (II)] - AND of remote trigger and 3 vertical signals
  
 
== Summary of necessary electronics and spares available at IU ==
 
== Summary of necessary electronics and spares available at IU ==
 
* 1 Bertan 313B High Voltage Supply - several spares at IU
 
* 1 Bertan 313B High Voltage Supply - several spares at IU
* 2 LeCroy 429A Fan-outs - 1 spare at IU
+
* 1 Phillips 726 Level Translator - several spares available at IU
* 2 LeCroy 825E Discriminators (3 and 4 channels) - 2 spares available at IU, also LeCroy 623B Octal Discriminator, with 7 working channels at IU, also 1 EG&G T122/NL discriminator with 4 channels available at IU
+
* 1 LRS 621L Discriminator (4 channels) - '''1 spare 621BL with 1 broken channel at IU'''
* 1 LRS 621L Discriminator (4 channels) - 1 spare 621BL with 1 broken channel at IU
+
* 1 LeCroy 623B Octal Discriminator (7 channels) - '''1 spare at IU'''
* 1 Phillips 726 Level Translator - 1 spare available at IU
+
* 1 Phillips 755 Logic Unit (need 4 2-way ANDs channels)
+
* 2 LeCroy 465 Coincidence Units (need 3 channels of 2-way ANDs on each, 6 total) - 1 spare available at IU, 1 channel needs output to be less than 100 ns.
+
 
* 1 LRS 365AL Logic Unit (2-way OR + VETO for final trigger) - (using only 1 channel, other channel is free)
 
* 1 LRS 365AL Logic Unit (2-way OR + VETO for final trigger) - (using only 1 channel, other channel is free)
 +
* 2 LeCroy 429A Fan-outs - 1 spare at IU
 +
* 1 Phillips 755 Logic Unit (need 4 2-way ANDs channels) - '''no spares'''
 +
<!-- * 2 LeCroy 825E Discriminators (3 and 4 channels) - 2 spares available at IU, also LeCroy 623B Octal Discriminator, with 7 working channels at IU, also 1 EG&G T122/NL discriminator with 4 channels available at IU -->
 +
* 2 LeCroy 465 Coincidence Units (need 3 channels of 2-way ANDs on each, 6 total) - '''2 spares available at IU, for one of them, 1 channel needs output to be less than 100 ns.'''

Latest revision as of 14:23, 3 November 2011

List of electronics to be used (links are to Fermilab)

Picture of electronics setup.


Summary of necessary electronics and spares available at IU

  • 1 Bertan 313B High Voltage Supply - several spares at IU
  • 1 Phillips 726 Level Translator - several spares available at IU
  • 1 LRS 621L Discriminator (4 channels) - 1 spare 621BL with 1 broken channel at IU
  • 1 LeCroy 623B Octal Discriminator (7 channels) - 1 spare at IU
  • 1 LRS 365AL Logic Unit (2-way OR + VETO for final trigger) - (using only 1 channel, other channel is free)
  • 2 LeCroy 429A Fan-outs - 1 spare at IU
  • 1 Phillips 755 Logic Unit (need 4 2-way ANDs channels) - no spares
  • 2 LeCroy 465 Coincidence Units (need 3 channels of 2-way ANDs on each, 6 total) - 2 spares available at IU, for one of them, 1 channel needs output to be less than 100 ns.