Difference between revisions of "List of FCAL Beamtest Electronics"

From GlueXWiki
Jump to: navigation, search
(List of electronics to be used (links are to Fermilab))
Line 16: Line 16:
 
** the 4-way OR signal of the VETO counters should be put in VETO
 
** the 4-way OR signal of the VETO counters should be put in VETO
 
* [http://www-esd.fnal.gov/esd/catalog/main/lcrynim/429a-spec.htm LeCroy 429A Logic Fan-In/Out (I)] - FAN-OUT of remote trigger into 10 channels for coincidence with trigger modules. The front panel switch should be set to "'''1x16'''" so that the output of the discriminated remote trigger is fanned out into all 16 OUTs.
 
* [http://www-esd.fnal.gov/esd/catalog/main/lcrynim/429a-spec.htm LeCroy 429A Logic Fan-In/Out (I)] - FAN-OUT of remote trigger into 10 channels for coincidence with trigger modules. The front panel switch should be set to "'''1x16'''" so that the output of the discriminated remote trigger is fanned out into all 16 OUTs.
 +
* [http://www-esd.fnal.gov/esd/catalog/main/psnim/755-spec.htm Phillips 755 Quad 4-Fold Logic Unit] - AND of remote trigger and 4 outside VETO counters
 
* [http://www-esd.fnal.gov/esd/catalog/main/lcrynim/465-spec.htm LeCroy 465 Triple 4-Fold Logic Unit (I)] - AND of remote trigger and 3 horizontal signals
 
* [http://www-esd.fnal.gov/esd/catalog/main/lcrynim/465-spec.htm LeCroy 465 Triple 4-Fold Logic Unit (I)] - AND of remote trigger and 3 horizontal signals
 
* [http://www-esd.fnal.gov/esd/catalog/main/lcrynim/465-spec.htm LeCroy 465 Triple 4-Fold Logic Unit (II)] - AND of remote trigger and 3 vertical signals
 
* [http://www-esd.fnal.gov/esd/catalog/main/lcrynim/465-spec.htm LeCroy 465 Triple 4-Fold Logic Unit (II)] - AND of remote trigger and 3 vertical signals
* [http://www-esd.fnal.gov/esd/catalog/main/psnim/755-spec.htm Phillips 755 Quad 4-Fold Logic Unit] - AND of remote trigger and 4 outside VETO counters
 
  
 
== Summary of necessary electronics and spares available at IU ==
 
== Summary of necessary electronics and spares available at IU ==

Revision as of 14:18, 3 November 2011

List of electronics to be used (links are to Fermilab)

Picture of electronics setup.


Summary of necessary electronics and spares available at IU

  • 1 Bertan 313B High Voltage Supply - several spares at IU
  • 2 LeCroy 429A Fan-outs - 1 spare at IU
  • 2 LeCroy 825E Discriminators (3 and 4 channels) - 2 spares available at IU, also LeCroy 623B Octal Discriminator, with 7 working channels at IU, also 1 EG&G T122/NL discriminator with 4 channels available at IU
  • 1 LRS 621L Discriminator (4 channels) - 1 spare 621BL with 1 broken channel at IU
  • 1 Phillips 726 Level Translator - 1 spare available at IU
  • 1 Phillips 755 Logic Unit (need 4 2-way ANDs channels)
  • 2 LeCroy 465 Coincidence Units (need 3 channels of 2-way ANDs on each, 6 total) - 1 spare available at IU, 1 channel needs output to be less than 100 ns.
  • 1 LRS 365AL Logic Unit (2-way OR + VETO for final trigger) - (using only 1 channel, other channel is free)