Difference between revisions of "Mar 7, 2019 Calorimeter"

From GlueXWiki
Jump to: navigation, search
(Tentative Agenda)
(Tentative Agenda)
Line 46: Line 46:
 
# Announcements
 
# Announcements
 
# Action Items
 
# Action Items
#* Tolga: Will briefly update on FCAL pedestal code project for group's information. Was focused on later agenda item so I did not produce updated plots today. Talk: https://halldweb.jlab.org/DocDB/0039/003939/001/FCALPEDESTALa.pdf
+
#* Tolga: Will briefly update on FCAL pedestal code project for group's information. Was focused on later agenda item so I did not produce updated plots today. Talk: https://halldweb.jlab.org/DocDB/0039/003939/001/FCALPEDESTALa.pdf ... The code is located here /w/halld-scifs17exp/terbora/JEventProcessor_ped_test.cc  
The code is located here /w/halld-scifs17exp/terbora/JEventProcessor_ped_test.cc  
+
 
#Run Updates
 
#Run Updates
 
## FCAL
 
## FCAL

Revision as of 13:28, 7 March 2019

Meeting Time: 11:00 a.m.

  1. To join via a Web Browser, go to the page [1] https://bluejeans.com/907185247.
  2. To join via Polycom room system go to the IP Address: 199.48.152.152 (bjn.vc) and enter the meeting ID: 907185247.
  3. To join via phone, use one of the following numbers and the Conference ID: 907185247.
    • US or Canada: +1 408 740 7256 or
    • US or Canada: +1 888 240 2560
  4. Upon connection all microphones are automatically muted. To unmute your mike on a Polycom or equivalent unit, enter *4. Unmuting on a computer is trivial as there is a microphone button than can be clicked.
  5. More information on connecting to bluejeans is available.

Participant Direct Lines

  • JLab Phone in CC L207 is 757-269-7084 (usual room)
  • JLab Phone: in CC F326 is 757-269-6460
  • Phone in the Regina Video-conference Suite is 306-585-4204
  • Athens Phone: in Christina's office is 011-30-210-727-6947

References

  1. FCAL HDFCAL log book
  2. BCAL HDBCAL log book

Goals for Calorimetry Group

  1. Determine preliminary photon reconstruction efficiencies as a function of E, phi and theta in data and simulation with a point-to-point precision of at least 5%.
  2. Measure systematics of pi0/eta mass calibration as a function of detector position to a precision of at east 5 MeV.
  3. Demonstrate agreement of photon reconstruction efficiency and resolution between data and simulation as a function of E, phi and theta to within 5%.

Action Items

Short term items:

  1. Complete Calorimeter work packages
  1. BCAL: Check pulsing rate of LED triggers when FP trigger bit is missing (start with early runs in fall 2018). With discerning software, check pulsing rate of later runs where it appeared that the downstream FP LED bit was not firing. (Ahmed)
  2. BCAL: Check that latest gain ratios are uploaded for spring 2018 (Mark).

Long term items:

  1. From Mike's work: -cos(phi) type dependence in the data and a phi dependence at the downstream end of the bcal. See Sep 21, 2017 Calorimeter Meeting.
  2. FCAL: It has been noticed that the pi0 mass shifts when the LED pulser runs at high rate. This is still not understood. See Log Entry 3595928 and references. Several runs have been taken in raw mode. These runs exhibit the shift in pi0 mass with LED running at 1 kHz. There is a need to analyze these to try to determine the cause:
    1. 50634 - FCAL Green LED: 1kHz, 29 V, Livetime is 9%, 1.7 M events
    2. 50635 - FCAL Violet LED: 1kHz, 22 V, Livetime is 9%, 1.4 M events
    3. 50636 - FCAL Blue LED: 1kHz, 15 V, Livetime is 9%, 1.5 M events

Tentative Agenda

  1. Announcements
  2. Action Items
  3. Run Updates
    1. FCAL
    2. BCAL
  4. Calibrations
  5. Reconstruction and Simulation
  6. Monitoring
  7. NIM articles
  8. Any other business

Minutes

Attending: