Difference between revisions of "Mattione Update 04302014"
From GlueXWiki
(→π+ PID) |
(→π+ PID) |
||
Line 12: | Line 12: | ||
** With DCutAction_ThrownTopology, DCutAction_AllTruePID @ +/- 5 σ matching. | ** With DCutAction_ThrownTopology, DCutAction_AllTruePID @ +/- 5 σ matching. | ||
** TBT is time-based tracking. | ** TBT is time-based tracking. | ||
− | ** For track time, order of preference is: BCAL, TOF, FCAL, TBT | + | ** For track time, order of preference is: BCAL, TOF, FCAL, TBT. Histograms only filled when that detector is selected. |
+ | *** Large # of FCAL matches: perhaps track/TOF matching too restrictive? | ||
+ | *** Large # of TBT tracks: no detector match | ||
** Uncertainties used for pull (and PID) calculations are hard-coded. | ** Uncertainties used for pull (and PID) calculations are hard-coded. | ||
** Histograms from DHistogramAction_PID | ** Histograms from DHistogramAction_PID | ||
Line 26: | Line 28: | ||
** Yellow line at pull = 0.0 just to guide the eye. | ** Yellow line at pull = 0.0 just to guide the eye. | ||
** low-θ tracks being matched to ST & BCAL hits indicates problems with hit-matching criteria. | ** low-θ tracks being matched to ST & BCAL hits indicates problems with hit-matching criteria. | ||
− | ** For track time, order of preference is: BCAL, TOF, FCAL, TBT | + | ** For track time, order of preference is: BCAL, TOF, FCAL, TBT. Histograms only filled when that detector is selected. |
** Histograms from DHistogramAction_GenReconTrackComparison | ** Histograms from DHistogramAction_GenReconTrackComparison | ||
{| class="wikitable" | {| class="wikitable" |
Revision as of 21:35, 28 April 2014
n3pi Cut Study
- Run 9003 (no EM background), ~5 MegaEvents, searching for γp→π+π+π-(n)
- Reconstructed Signal Combos (DCutAction_ThrownTopology, DCutAction_AllTruePID) (% is Signal Remaining)
- All is 34361 combos (events) of 59562 thrown n3pi in ~5 MegaEvent sample: 57.7% Acceptance
- +/- 5σ cut on Thrown <---> Detected matching for DCutAction_AllTruePID.
π+ PID
- 1D Pulls of skim tracks (tThrown - tReconstructed)/σt (Reconstructed)
- With DCutAction_ThrownTopology, DCutAction_AllTruePID @ +/- 5 σ matching.
- TBT is time-based tracking.
- For track time, order of preference is: BCAL, TOF, FCAL, TBT. Histograms only filled when that detector is selected.
- Large # of FCAL matches: perhaps track/TOF matching too restrictive?
- Large # of TBT tracks: no detector match
- Uncertainties used for pull (and PID) calculations are hard-coded.
- Histograms from DHistogramAction_PID
- 2D Pulls of π+'s (tThrown - tReconstructed)/σt (Reconstructed) with no cuts except +/- 5 σ thrown matching.
- Yellow line at pull = 0.0 just to guide the eye.
- low-θ tracks being matched to ST & BCAL hits indicates problems with hit-matching criteria.
- For track time, order of preference is: BCAL, TOF, FCAL, TBT. Histograms only filled when that detector is selected.
- Histograms from DHistogramAction_GenReconTrackComparison