Difference between revisions of "May 3, 2019 - PrimEx-Eta Meeting"
From GlueXWiki
(Created page with "== Time and Place == * Time: Friday, May 3, 2019 2:00 pm EST. * Room: CEBAF Center, Room F227 == Meeting Connections == # If joining via web browser, go to [https://bluejean...") |
m (→Slides) |
||
(3 intermediate revisions by 2 users not shown) | |||
Line 10: | Line 10: | ||
#* US or Canada: +1 888 240 2560 | #* US or Canada: +1 888 240 2560 | ||
# If joining via Polycom room system go to the IP Address: 199.48.152.152 ([http://bjn.vc bjn.vc]) and enter the meeting ID: 7572695553. | # If joining via Polycom room system go to the IP Address: 199.48.152.152 ([http://bjn.vc bjn.vc]) and enter the meeting ID: 7572695553. | ||
+ | |||
+ | == Slides == | ||
+ | |||
+ | [https://halldweb.jlab.org/primexd/meetings/meeting_5_3_19/compton Accidentals in Compton reconstruction] | ||
+ | |||
+ | [https://userweb.jlab.org/~andrsmit/meetingPlots/plots_05_03/slides_05_03_19.pdf Primakoff Yields and Eta Angular Distribution] | ||
== Minutes == | == Minutes == | ||
+ | |||
+ | # CompCal Calibrations | ||
+ | #* Sasha showed that the CompCal energies from reconstructed compton events are shifted by up to 200 MeV. We will need to develop a procedure for calibration. | ||
+ | #* Potentially we can use compton events for energy calibrations in addition to the snake scans. | ||
+ | # Eta distributions | ||
+ | #* Drew's slides with eta yields and angular distribution: [https://userweb.jlab.org/~andrsmit/plots_05_03/slides_05_03_19.pdf eta_yield_slides_05_03_19.pdf] | ||
+ | #* Next week, will provide more detailed plots with progression of individual cuts and their impacts on the distribution. | ||
+ | #* The angular distributions still need to have accidental and empty target subtractions applied. | ||
+ | # Sean is working on timing alignments, so we will need to coordinate with him | ||
+ | #* Drew pointed out that the detector alignments with respect to the rf shifts a few times over the course of the run period. In particular these ranges need separate alignments (there could be other shifts outside of these run ranges): | ||
+ | * 61426-61447 | ||
+ | * 61462-61568 | ||
+ | * 61621-61723 | ||
+ | * 61727-61743 | ||
+ | * 61744-61912 |
Latest revision as of 13:42, 24 May 2019
Time and Place
- Time: Friday, May 3, 2019 2:00 pm EST.
- Room: CEBAF Center, Room F227
Meeting Connections
- If joining via web browser, go to [1] https://jlab.bluejeans.com/7572695553/
- If joining via phone, use one of the following numbers and the Conference ID: 7572695553.
- US or Canada: +1 408 740 7256 or
- US or Canada: +1 888 240 2560
- If joining via Polycom room system go to the IP Address: 199.48.152.152 (bjn.vc) and enter the meeting ID: 7572695553.
Slides
Accidentals in Compton reconstruction
Primakoff Yields and Eta Angular Distribution
Minutes
- CompCal Calibrations
- Sasha showed that the CompCal energies from reconstructed compton events are shifted by up to 200 MeV. We will need to develop a procedure for calibration.
- Potentially we can use compton events for energy calibrations in addition to the snake scans.
- Eta distributions
- Drew's slides with eta yields and angular distribution: eta_yield_slides_05_03_19.pdf
- Next week, will provide more detailed plots with progression of individual cuts and their impacts on the distribution.
- The angular distributions still need to have accidental and empty target subtractions applied.
- Sean is working on timing alignments, so we will need to coordinate with him
- Drew pointed out that the detector alignments with respect to the rf shifts a few times over the course of the run period. In particular these ranges need separate alignments (there could be other shifts outside of these run ranges):
* 61426-61447 * 61462-61568 * 61621-61723 * 61727-61743 * 61744-61912