May 8, 2014 Calorimetry

From GlueXWiki
Revision as of 13:57, 8 May 2014 by Elton (Talk | contribs) (Minutes)

Jump to: navigation, search

Teleconference Time: 11:00 a.m. EST

  • ESNET (Number is 8542553) and SeeVogh session (GlueX Calorimetry meeting room)
  • Phone connection only upon request.
    • +1-866-740-1260 : US+Canada
    • +1-303-248-0285 : International
    • then enter participant code: 3421244# (remember the "#").
    • or www.readytalk.com (and code without the #)

Participant Direct Lines

  • JLab Phone: in CC F326 is 757-269-6460 (usual room)
  • JLab Phone in CC L207 is 757-269-7084
  • Phone in the Regina Videoconference Suite is 306-585-4204
  • Athens Phone: in Christina's office is 011-30-210-727-6947

Items for followup from previous meeting(s)

  • BCAL: Check max ratings for MPPCs (Elton).

Tentative Agenda

  1. Announcements
  2. Collaboration Meeting May 12-14
  3. Action Items
  4. FCAL
  5. BCAL
  6. Reconstruction and Simulation
  7. TDR update
  8. Calibration
  9. Any other business

Minutes

Attendees: Manuel, Laura, Shayne, Will, Mark, Zisis, Elton, John L., David, Yi (JLab); Andrei, Teigan (UofR), Matt (IU).

  1. Announcements
    • CEBAF delivered 10.5 GeV beam to the tagger dump last night!
  2. Collaboration Meeting May 12-14
  3. Action Items
  4. FCAL
    • HDFCAL log book (John)
    • Fcal detector continues to work with no known problems
    • New firmware installed on Fadcs seems to have addressed all known problems with the Fadcs
    • Log book entry shows timing of LED pulser run, with the timing determined by the IU "linear interpolation" method
    • David: Note that the hardware this algorithm is not currently implemented in the hardware and plans for implementation are not clear
    • Timing of single events shows regions of similar timing and the pattern of timing is correlated with crates.
    • Problem is likely due to timing distribution to the crates
    • Pedestals: First look at overnight pedestal run shows some 3 hour structure (as for the BCAL) , but with much reduced amplitude (~0.6 channels)
  5. BCAL
    1. HDBCAL log book (Mark)
    • First look at pedestal stability in BCAL
    • ~3 hour period for baseline oscillations with detector powered on
    • Same structure seen in data (not yet entered into the log) for pedestals with the power off, but at a reduced amplitude
    • Oscillations seem to correlate with the temperatures in the crates, which vary by about 2 degF. [Note: temperature variations of the MPPC chillers has a period of about 20 min and voltages are very stable.]
    • Matt: Each Fcal base has a temperature sensor that could be used as a reference for temperature variations in the hall. They accessible through the CAN controller that has a network address to access data.
    • Changes in the pedestal when power is shut off to the MPPCs are about 20 counts. However, in one slot of one crate, they show variations of order 70-80 counts, which is likely not physical.
  6. Reconstruction and Simulation
  7. TDR update
  8. Calibration
  9. Any other business