Mcsmear updates

From GlueXWiki
Revision as of 22:37, 21 April 2015 by Sdobbs (Talk | contribs)

Jump to: navigation, search

Current Settings

General Comments

Smearing is performed by adding a Gaussian function, unless otherwise described.

TRIGGER_LOOKBACK_TIME = -100 ns

CDC

name value comment
CDC_TIME_WINDOW 1000. readout window (ns)
CDC_PEDESTAL_SIGMA 50.0 charge smearing factor
CDC_THRESHOLD_FACTOR 4.0 sparsification threshold = CDC_THRESHOLD_FACTOR* CDC_PEDESTAL_SIGMA
CDC_TDRIFT_SIGMA 2.8181818181818e-9 drift time smearing width*1.0e-9 (ns)

[more in hdgeant]

Noise parameterization from 2007.

FDC

name value comment
FDC_TIME_WINDOW 1000. readout window (ns)
FDC_CATHODE_SIGMA 150.0 cathode charge smearing factor
FDC_PED_NOISE -> charge smearing factor = -0.0938 + 0.0485*FDC_CATHODE_SIGMA
FDC_THRESHOLD_FACTOR 4.0 sparsification threshold = FDC_THRESHOLD_FACTOR * FDC_PED_NOISE
FDC_TDRIFT_SIGMA 1.0-9 drift time smearing width*1.0e-9 (ns) [both wire and cathode]

[more in hdgeant]

Noise parameterization from 2007 [only wires].

FCAL

BCAL