Difference between revisions of "Meetings-5-6-2021"

From GlueXWiki
Jump to: navigation, search
(Agenda)
(Minutes)
Line 19: Line 19:
 
# Tracking
 
# Tracking
 
# Detector related reports
 
# Detector related reports
 +
#* FA125
 +
#** Naomi relayed that Cody has a suspicion as to what might be the cause of the trigger number bug but has not had a chance to test this yet. 
 
#* CDC
 
#* CDC
 +
#** Naomi summarized the work on [https://halldweb.jlab.org/wiki/index.php/GlueX_PID_Meeting,_May_4,_2021 dE/dx comparisons between measured and sim data] using the CDC space-charge correction with data from phi, rho and K+Sigma0. The ratio between corrected measured and sim has little dependence on momentum, and dE/dx from amplitude is similar for p, K and pi in all channels studied (integral is more variable). The scaling factors necessary to match the measured corrected data to the sim are now in CCDB (/CDC/dedx_theta/dedx_amp_scale). They are different for 2017 because the gains were calibrated to match an older simulation. The scaled corrected dE/dx is consistent between run periods and shows good agreement between measured and sim, except that the simulated resolution is better.
 
#* FDC
 
#* FDC
 
# GEM-TRD
 
# GEM-TRD
 
# Other
 
# Other

Revision as of 14:47, 6 May 2021

  1. Instructions for Bluejeans meeting connection
  2. Meeting ID: 290664653
  3. To join via a Web Browser, go to the page [1] https://bluejeans.com/290664653.

Thu 5/6/2021 2pm

Agenda

  1. Tracking
  2. Detector related reports
    1. Ks alignment update (issues)
  3. GEM-TRD
  4. Other

Minutes

  1. Tracking
  2. Detector related reports
    • FA125
      • Naomi relayed that Cody has a suspicion as to what might be the cause of the trigger number bug but has not had a chance to test this yet.
    • CDC
      • Naomi summarized the work on dE/dx comparisons between measured and sim data using the CDC space-charge correction with data from phi, rho and K+Sigma0. The ratio between corrected measured and sim has little dependence on momentum, and dE/dx from amplitude is similar for p, K and pi in all channels studied (integral is more variable). The scaling factors necessary to match the measured corrected data to the sim are now in CCDB (/CDC/dedx_theta/dedx_amp_scale). They are different for 2017 because the gains were calibrated to match an older simulation. The scaled corrected dE/dx is consistent between run periods and shows good agreement between measured and sim, except that the simulated resolution is better.
    • FDC
  3. GEM-TRD
  4. Other