= Minutes =
 
= Minutes =
Line 31: Line 30:
 
- Lubomir about the SEM results: On the wire samples some small crystals (~3um) are seen containing sulfur, Olga counted about 25 of these on 2cm wire length; too small quantity to account for the copper damage on the cathodes. On the EPDM surface - no conductivity and very low yield from the microscope - still one see some sulfur on the used EPDM, and much less or nothing on the virgin EPDM and on the prototype EPDM. Dave will check if the virgin and used EPDMs are from the same batch.
 
- Lubomir about the SEM results: On the wire samples some small crystals (~3um) are seen containing sulfur, Olga counted about 25 of these on 2cm wire length; too small quantity to account for the copper damage on the cathodes. On the EPDM surface - no conductivity and very low yield from the microscope - still one see some sulfur on the used EPDM, and much less or nothing on the virgin EPDM and on the prototype EPDM. Dave will check if the virgin and used EPDMs are from the same batch.
 
    
 
    
 +
- Results from the vacuum chamber (Vlad's) experiment: it was running from last Thursday (end of the day) till Monday morning, pictures linked above. One clearly sees damages on the EPDM, just a little on the Viton sample and no damages are seen on the Viton+grease sample. The sample are now with Olga and will have SEM results next week. Bill proposed to make another sample with Viton+grease with curving shape to have more potentially damaged area and then measure if the resistance has changed. Vlad will check the resistance of the samples that we have now. On Tuesday we started the same test except there's no water inside the gas volume.
  
- Three other test experiments are running. One with production cathodes and a wire frame that started more than two weeks ago. Second one with similar samples using the small-scale prototype, running since yesterday when we were able to fix the HV. The third one is the Vlad's experiment using the vacuum chamber (picture linked) with same samples (EPDM, Viton with/without Apiezon) with same gas, but no HV, with some water inside to create moisture, all this heated with a lamp (only during the day) up to 80degC. It started yesterday; we will open the chamber on Monday.
+
- As of now we see two solutions of the corrosion problem: using the technology that we used already for the third and fourth packages, i.e. Viton+grease, or in addition to that, covering big areas on the cathode including all the traces with Kapton glued with Hysol. Using Kapton foils doesn't seem to create leakage but we tested this on a flat Lexan sheet. We decided to use the standard technology for the second package, i.e. only Viton+grease. When we come to the first package (in about two-three month from now) we will discuss again the use of Kapton; there we may have to use it if we are going to re-use the cathodes from the former second package since some of the channels have to be fixed with conductive ink. Of course we will wait for the latest SEM results
 +
before continuing with this procedure.
  
== Production ==
+
== Conductive tape technology ==
 +
 
 +
<!--
  
 
- Dave: cathode #61 (type-3) that was supposed to be the first for package #2 showed a problem: the Mylar peeled off on the second day after gluing it. The surface is tacky. Bill will consult with the manufacturer of the Hysol epoxy and we will do several experiments to test it. The frame was re-used, Casey sanded it with #220 as he did for the frames that were converted to type-2 from type-1, but using different sanding tool. Tomorrow we will see if the surface will be still tacky and will re-sand it in the same way as for the converted frames.  
 
- Dave: cathode #61 (type-3) that was supposed to be the first for package #2 showed a problem: the Mylar peeled off on the second day after gluing it. The surface is tacky. Bill will consult with the manufacturer of the Hysol epoxy and we will do several experiments to test it. The frame was re-used, Casey sanded it with #220 as he did for the frames that were converted to type-2 from type-1, but using different sanding tool. Tomorrow we will see if the surface will be still tacky and will re-sand it in the same way as for the converted frames.  

Revision as of 12:15, 17 August 2012

August 16, 2012 FDC meeting

Agenda

  1. Cathode production Construction Tracking (Dave)
  2. Cathode corrosion
    • Status [1]
    • Possible procedure changes
  3. Conductive tape technology
  4. Engineering (Bill)
    • Cathode strong-back
    • Other: epoxy tests
  5. Electronics (Chris, Nick)
    • PCBs
  6. TDR, pages 132-145 (Lubomir)
  7. Other


Minutes

Participants: Eugene, Bill, Dave, Simon, Vlad, Beni, and Lubomir

Cathode production

- Dave: working on 8 new cathodes to be used in the second package. The bottleneck is the card gluing since we have not decided if we want to change the procedures.

Cathode corrosion

- Lubomir about the SEM results: On the wire samples some small crystals (~3um) are seen containing sulfur, Olga counted about 25 of these on 2cm wire length; too small quantity to account for the copper damage on the cathodes. On the EPDM surface - no conductivity and very low yield from the microscope - still one see some sulfur on the used EPDM, and much less or nothing on the virgin EPDM and on the prototype EPDM. Dave will check if the virgin and used EPDMs are from the same batch.

- Results from the vacuum chamber (Vlad's) experiment: it was running from last Thursday (end of the day) till Monday morning, pictures linked above. One clearly sees damages on the EPDM, just a little on the Viton sample and no damages are seen on the Viton+grease sample. The sample are now with Olga and will have SEM results next week. Bill proposed to make another sample with Viton+grease with curving shape to have more potentially damaged area and then measure if the resistance has changed. Vlad will check the resistance of the samples that we have now. On Tuesday we started the same test except there's no water inside the gas volume.

- As of now we see two solutions of the corrosion problem: using the technology that we used already for the third and fourth packages, i.e. Viton+grease, or in addition to that, covering big areas on the cathode including all the traces with Kapton glued with Hysol. Using Kapton foils doesn't seem to create leakage but we tested this on a flat Lexan sheet. We decided to use the standard technology for the second package, i.e. only Viton+grease. When we come to the first package (in about two-three month from now) we will discuss again the use of Kapton; there we may have to use it if we are going to re-use the cathodes from the former second package since some of the channels have to be fixed with conductive ink. Of course we will wait for the latest SEM results before continuing with this procedure.

Conductive tape technology