Difference between revisions of "Newest preamp"
From GlueXWiki
Line 3: | Line 3: | ||
*Outer plenum added to CDC prototype to prevent leaks | *Outer plenum added to CDC prototype to prevent leaks | ||
*New modified HVB | *New modified HVB | ||
− | |||
*2050V | *2050V | ||
− | *Comparison of | + | *Comparison of modified preamp (preamp4 with terminating resistors removed) and its predecessor (preamp4) |
+ | |||
+ | Below: cosmics with newest modified preamp (left) and preamp4 (right) Blue histograms are tracked hits. | ||
+ | |||
+ | {| border="0" cellpadding="2" | ||
+ | |width="420pt"| | ||
+ | [[Image:run_31646_thr5_amp6.png|thumb|420px|Max amplitude histo for cosmics, new fADC, modified HVB, modified preamp, mixed 50/50 at 60 sccm 2050V]] | ||
+ | |width="420pt"| | ||
+ | [[Image:run_31599_amp6.png|thumb|420px|Max amplitude histo for cosmics, new fADC, modified HVB, mixed 50/50 at 60 sccm 2050V]] | ||
+ | |} | ||
+ | |||
+ | |||
+ | |||
Below: 55Fe spectra with preamp 4 and Struck ADCs set to half-range, 550mV | Below: 55Fe spectra with preamp 4 and Struck ADCs set to half-range, 550mV |
Revision as of 08:29, 20 April 2011
- 50/50 mixed Ar, CO2
- Recalibrated MFCs
- Outer plenum added to CDC prototype to prevent leaks
- New modified HVB
- 2050V
- Comparison of modified preamp (preamp4 with terminating resistors removed) and its predecessor (preamp4)
Below: cosmics with newest modified preamp (left) and preamp4 (right) Blue histograms are tracked hits.
Below: 55Fe spectra with preamp 4 and Struck ADCs set to half-range, 550mV
Below: 55Fe spectra with newest preamp (preamp4 minus terminating resistors) and Struck ADCs set to full-range, 1.1V