## [https://logbooks.jlab.org/entry/3621347 Log Entry 3621347] FCAL Non-linear Response in MC (Matt)
 
## [https://logbooks.jlab.org/entry/3621347 Log Entry 3621347] FCAL Non-linear Response in MC (Matt)
 
# Monitoring
 
# Monitoring
#[https://halldweb.jlab.org/wiki/images/e/eb/Channel_Radiation_Damage.pdf Radiation Damage in Inner Blocks of FCAL]
+
##[https://halldweb.jlab.org/wiki/images/e/eb/Channel_Radiation_Damage.pdf Radiation Damage in Inner Blocks of FCAL]
 
# NIM articles
 
# NIM articles
 
# Any other business
 
# Any other business

Revision as of 12:02, 15 November 2018

Meeting Time: 11:00 a.m.

  1. To join via a Web Browser, go to the page [1] https://bluejeans.com/907185247.
  2. To join via Polycom room system go to the IP Address: 199.48.152.152 (bjn.vc) and enter the meeting ID: 907185247.
  3. To join via phone, use one of the following numbers and the Conference ID: 907185247.
    • US or Canada: +1 408 740 7256 or
    • US or Canada: +1 888 240 2560
  4. Upon connection all microphones are automatically muted. To unmute your mike on a Polycom or equivalent unit, enter *4. Unmuting on a computer is trivial as there is a microphone button than can be clicked.
  5. More information on connecting to bluejeans is available.

Participant Direct Lines

  • JLab Phone in CC L207 is 757-269-7084 (usual room)
  • JLab Phone: in CC F326 is 757-269-6460
  • Phone in the Regina Video-conference Suite is 306-585-4204
  • Athens Phone: in Christina's office is 011-30-210-727-6947

Action Items

  1. FCAL: Cross check MC changes by Richard to make sure that gains are not affected in both Geant3 and Geant4 (Matt/IHEP)
  2. Fix FCAL online monitoring plugin to properly plot low level digi quantities in 2D displays. 2D display of pedestal is hard to get because occupancy plot is filled in a different loop. (Tolga)

-Tolga: Will explain progress after analyzing and playing with JEventProcessor plugin.Cannot promise final plots unfortunately due to various reasons.

  1. Complete after new launch
  2. From Mike's work: -cos(phi) type dependence in the data and a phi dependence at the downstream end of the bcal. See Sep 21, 2017 Calorimeter Meeting.

Goals for Calorimetry Group

  1. Determine preliminary photon reconstruction efficiencies as a function of E, phi and theta in data and simulation with a point-to-point precision of at least 5%.
  2. Measure systematics of pi0/eta mass calibration as a function of detector position to a precision of at east 5 MeV.
  3. Demonstrate agreement of photon reconstruction efficiency and resolution between data and simulation as a function of E, phi and theta to within 5%.

References

  1. FCAL HDFCAL log book
  2. BCAL HDBCAL log book

Tentative Agenda

  1. Announcements
  2. Action Items
  3. Run Updates
    1. FCAL
    2. BCAL
  4. Calibrations
    1. BCAL timing: Mark has calibrated the BCAL timing offsets up to run up to run 51377.
    2. Non linear corrections for pi0 gain_calibrations for the BCAL: An Update File:Non linear corrections update.pdf.
  5. Reconstruction and Simulation
    1. Log Entry 3621347 FCAL Non-linear Response in MC (Matt)
  6. Monitoring
    1. Radiation Damage in Inner Blocks of FCAL