Difference between revisions of "Offline Monitoring Data Validation"

From GlueXWiki
Jump to: navigation, search
(Checklist)
(Checklist)
Line 37: Line 37:
 
** Check BCAL Recon. 2 - Reference: [ [https://halldweb.jlab.org/work/halld2/data_monitoring/RunPeriod-2017-01/mon_ver29/Run030780/HistMacro_BCALReconstruction_p2.png link] ]
 
** Check BCAL Recon. 2 - Reference: [ [https://halldweb.jlab.org/work/halld2/data_monitoring/RunPeriod-2017-01/mon_ver29/Run030780/HistMacro_BCALReconstruction_p2.png link] ]
 
** Check BCAL Matching - Reference:  [ [https://halldweb.jlab.org/work/halld2/data_monitoring/RunPeriod-2017-01/mon_ver29/Run030780/HistMacro_Matching_BCAL.png link] ]
 
** Check BCAL Matching - Reference:  [ [https://halldweb.jlab.org/work/halld2/data_monitoring/RunPeriod-2017-01/mon_ver29/Run030780/HistMacro_Matching_BCAL.png link] ]
 +
 +
<div class="toccolours mw-collapsible mw-collapsed">
 +
 +
Reference Plots
 +
 +
<div class="mw-collapsible-content">
 +
 +
<html>
 +
<a href="/work/halld2/data_monitoring/RunPeriod-2017-01/mon_ver29/Run030780/bcal_occupancy.png"><img src="/work/halld2/data_monitoring/RunPeriod-2017-01/mon_ver29/Run030780/bcal_occupancy.png" height="200"/></a>
 +
<a href="/work/halld2/data_monitoring/RunPeriod-2017-01/mon_ver29/Run030780/bcal_hist_eff.png"><img src="/work/halld2/data_monitoring/RunPeriod-2017-01/mon_ver29/Run030780/bcal_hist_eff.png" height="200"/></a>
 +
<a href="/work/halld2/data_monitoring/RunPeriod-2017-01/mon_ver29/Run030780/HistMacro_BCALReconstruction_p1"><img src="/work/halld2/data_monitoring/RunPeriod-2017-01/mon_ver29/Run030780/HistMacro_BCALReconstruction_p1" height="200"/></a>
 +
<a href="/work/halld2/data_monitoring/RunPeriod-2017-01/mon_ver29/Run030780/HistMacro_BCALReconstruction_p2.png"><img src="/work/halld2/data_monitoring/RunPeriod-2017-01/mon_ver29/Run030780/HistMacro_BCALReconstruction_p2.png" height="200"/></a>
 +
<a href="/work/halld2/data_monitoring/RunPeriod-2017-01/mon_ver29/Run030780/HistMacro_Matching_BCAL.png"><img src="/work/halld2/data_monitoring/RunPeriod-2017-01/mon_ver29/Run030780/HistMacro_Matching_BCAL.png" height="200"/></a>
 +
</html>
 +
</div>
 +
</div>
 +
 
* '''CDC'''
 
* '''CDC'''
 
** Check Occupancy - Reference: [ [https://halldweb.jlab.org/work/halld2/data_monitoring/RunPeriod-2017-01/mon_ver29/Run030780/CDC_occupancy.png link] ]
 
** Check Occupancy - Reference: [ [https://halldweb.jlab.org/work/halld2/data_monitoring/RunPeriod-2017-01/mon_ver29/Run030780/CDC_occupancy.png link] ]

Revision as of 15:58, 11 July 2018

This page contains the procedure for checking if production runs are of good quality and can be used for physics analysis.

Run Periods

Procedure

For each production run, do the following:

  • Go to the | Offline Run Browser page.
  • Follow the steps outlined in the checklist below.
  • Certify that each section is okay
    • (DB + script to be developed)
  • Set run status = 1 in RCDB
    • (script provided)

Run Statuses

  • -1 - unchecked
  • 0 - rejected (not physics-quality)
  • 1 - approved
  • 2 - approved long/"mode 8" data
  • 3 - calibration / systematic studies

Checklist

Reference run: 30780 (mon ver29, 1 file)

  • BCAL
    • Check Occupancy - Reference: [ link ]
    • Check Hit Efficiency - Reference: [ link ]
    • Check BCAL Recon. 1 - Reference: [ link ]
    • Check BCAL Recon. 2 - Reference: [ link ]
    • Check BCAL Matching - Reference: [ link ]

Reference Plots

  • CDC
    • Check Occupancy - Reference: [ link ]
    • Check Time-to-distance - Reference: [ link ]
  • FCAL
    • Check Occupancy - Reference: [ link ]
    • Check FCAL Hits 1 - Reference: [ link ]
    • Check FCAL Hits 2 - Reference: [ link ]
    • Check FCAL Clusters 1 - Reference: [ link ]
    • Check FCAL Recon. 1 - Reference: [ link ]
    • Check FCAL Recon. 2 - Reference: [ link ]
    • Check FCAL Matching - Reference: [ link ]
  • FDC
    • Check Package 1 Occupancy - Reference: [ link ]
    • Check Package 2 Occupancy - Reference: [ link ]
    • Check Package 3 Occupancy - Reference: [ link ]
    • Check Package 4 Occupancy - Reference: [ link ]
  • PS
    • Check Occupancy - Reference: [ link ]
    • Check Timing Alignment - Reference: [ link ]
  • SC
    • Check Occupancy - Reference: [ link ]
    • Check SC Recon. 1 - Reference: [ link ]
    • Check SC Recon. 2 - Reference: [ link ]
    • Check SC Matching - Reference: [ link ]
  • TAGH
    • Check Tagger Occupancy - Reference: [ link ]
    • Check TAGH Hits 2 - Reference: [ link ]
  • TAGM
    • Check Timing ADC-RF - Reference: [ link ]
    • Check Timing T-ADC - Reference: [ link ]
  • TOF
    • Check Occupancy - Reference: [ link ]
    • Check TOF Matching 1 - Reference: [ link ]
    • Check TOF Matching 2 - Reference: [ link ]
  • RF
    • Check timing offsets - Reference: [ link ]
      • Should be centered around zero
  • Timing
    • Check Calorimeter Timing - Reference: [ link ]
    • Check Drift Chamber Timing - Reference: [ link ]
    • Check PID System Timing - Reference: [ link ]
    • Check Tagger Timing - Reference: [ link ]
    • Check Track Matched Timing - Reference: [ link ]
    • Check Tagger/RF Timing - Reference: [ link ]
    • Check Tagger/SC Timing - Reference: [ link ]
  • Analysis
    • Tracking 1 - [ link ]
    • Tracking 3 - [ link ]
    • Check BCAL pi0 - Reference: [ link ]
    • Check BCAL/FCAL pi0 - Reference: [ link ]
    • Check p+2pi - Reference: [ link ]
    • Check p+3pi - Reference: [ link ]
    • Check p+pi0g - Reference: [ link ]