Difference between revisions of "PMT tiles missing after restarting data taking"
From GlueXWiki
(→Occupancy of the Issue) |
(→Occupancy of the Issue During Operation) |
||
Line 21: | Line 21: | ||
| North c1 r15 | | North c1 r15 | ||
| https://logbooks.jlab.org/entry/3772139 | | https://logbooks.jlab.org/entry/3772139 | ||
+ | |- | ||
+ | ! scope=row | 2020 Jan 15, 13:43 | ||
+ | | Yes | ||
+ | | South c2 r7 | ||
+ | | https://logbooks.jlab.org/entry/3764225 | ||
|- | |- | ||
|} | |} |
Revision as of 12:57, 28 January 2020
Description on the Symptoms
After restarting DAQ, the missing tiles can be seen on the occupancy plots on Rootspy (see an example image to the right).
Solution
- Stop the current run.
- Completely restart Coda (by pressing STOP button on the RCM GUI).
- Start Coda normally (Configure->Download->Prestart->Start)
- Call DIRC expert if problem was not resolved.
Occupancy of the Issue During Operation
Date | Resolved After DAQ Reboot | Box Tile | Log Post |
---|---|---|---|
2020 Jan 27, 15:18 | Yes | North c1 r15 | https://logbooks.jlab.org/entry/3772139 |
2020 Jan 15, 13:43 | Yes | South c2 r7 | https://logbooks.jlab.org/entry/3764225 |