Difference between revisions of "PMT tiles missing after restarting data taking"

From GlueXWiki
Jump to: navigation, search
(Occupancy of the Issue During Operation)
Line 1: Line 1:
 
[[File:DIRC_missing_tiles.png|400px|image:400 pixels|thumb|Thumbnailed image]]
 
[[File:DIRC_missing_tiles.png|400px|image:400 pixels|thumb|Thumbnailed image]]
 +
[[File:DIRC_missing_tiles_scalar.png|400px|image:400 pixels|thumb|Thumbnailed image]]
 +
  
 
= Description on the Symptoms =
 
= Description on the Symptoms =

Revision as of 13:09, 28 January 2020

Thumbnailed image
Thumbnailed image


Description on the Symptoms

After restarting DAQ, the missing tiles can be seen on the occupancy plots on Rootspy (see an example image to the right).

Solution

  1. Stop the current run.
  2. Completely restart Coda (by pressing STOP button on the RCM GUI).
  3. Start Coda normally (Configure->Download->Prestart->Start)
  4. Call DIRC expert if problem was not resolved.

Occupancy of the Issue During Operation

Date Resolved After DAQ Reboot Box Tile Log Post
2020 Jan 27, 15:18 Yes North c1 r15 https://logbooks.jlab.org/entry/3772139
2020 Jan 15, 13:43 Yes South c2 r7 https://logbooks.jlab.org/entry/3764225