Difference between revisions of "PMT tiles missing after restarting data taking"
From GlueXWiki
Line 1: | Line 1: | ||
− | [[File:DIRC_missing_tiles.png|400px|image:400 pixels|thumb| | + | [[File:DIRC_missing_tiles.png|400px|image:400 pixels|thumb|Missing tiles from North Box in Rootspy occupancy plot]] |
− | [[File:DIRC_missing_tiles_scalar.png|400px|image:400 pixels|thumb| | + | [[File:DIRC_missing_tiles_scalar.png|400px|image:400 pixels|thumb|Missing tiles from South Box in EPIC scalar plot]] |
Revision as of 13:10, 28 January 2020
Description on the Symptoms
After restarting DAQ, the missing tiles can be seen on the occupancy plots on Rootspy (see an example image to the right).
Solution
- Stop the current run.
- Completely restart Coda (by pressing STOP button on the RCM GUI).
- Start Coda normally (Configure->Download->Prestart->Start)
- Call DIRC expert if problem was not resolved.
Occupancy of the Issue During Operation
Date | Resolved After DAQ Reboot | Box Tile | Log Post |
---|---|---|---|
2020 Jan 27, 15:18 | Yes | North c1 r15 | https://logbooks.jlab.org/entry/3772139 |
2020 Jan 15, 13:43 | Yes | South c2 r7 | https://logbooks.jlab.org/entry/3764225 |