Difference between revisions of "Pair Spectrometer"

From GlueXWiki
Jump to: navigation, search
(Electronics)
 
(25 intermediate revisions by 2 users not shown)
Line 1: Line 1:
===Archive of the working drafts for the pair spectrometer proposal. ===
 
== [http://argus.phys.uregina.ca/gluex/DocDB/0011/001128/005/Hall_D_PS_10.doc Pair Spectrometer v10.0 (doc)]
 
== [http://argus.phys.uregina.ca/gluex/DocDB/0011/001128/003/Hall_D_PS_9.3.doc Pair Spectrometer v9.3] [http://argus.phys.uregina.ca/gluex/DocDB/0011/001128/003/Hall_D_PS_9.3.pdf pdf ]
 
== [http://argus.phys.uregina.ca/gluex/DocDB/0011/001128/002/Hall_D_PS_9.1.3.doc  Pair spectrometer proposal: Version presented to the Sept08 collaboration meeting]
 
== [[Media:Hall_D_PS_9.2.pdf|Pair Spectrometer draft 9]] first real Draft to Photon beam group
 
== [[Media:Hall_D_PS_7.doc|Pair Spectrometer draft 7]] with Jim's reordering
 
== [[Media:Hall_D_PS_6.doc|Pair spectrometer draft 6]] Hrachya's original version
 
 
 
=== Pair spectrometer overview ===
 
=== Pair spectrometer overview ===
 
[[Image:PairFig.jpg |350px]]
 
[[Image:PairFig.jpg |350px]]
  
  
=== Excel file with track calculations ===
+
==== 18D36 magnet ====
  
[[Media:PairSpec_overview.xlsx | pair spectrometer spreadsheet]]
 
 
===Proposed magnet BNL Type: 30D72.===
 
(Power supplies are also available)
 
----
 
 
[[image:30D72.jpg|250px]]
 
 
==== Drawings ====
 
==[http://argus.phys.uregina.ca/gluex/DocDB/0011/001158/001/d12-m-225-6-1.pdf assembly drawing]
 
 
====Pictures ====
 
 
<gallery>
 
<gallery>
 
image:30D72_waterPower.JPG|water power connections
 
image:30D72_waterPower.JPG|water power connections
Line 35: Line 15:
 
Image:30D72_coils1.JPG|coils1
 
Image:30D72_coils1.JPG|coils1
 
Image:30D72 coils2.JPG|coils2
 
Image:30D72 coils2.JPG|coils2
 +
Image:2012-06-05_07-33-29_980.jpg|Downstream end of the vacuum chamber
 +
Image:2012-06-05_07-33-42_340.jpg|Downstream end of the vacuum chamber
 
</gallery>
 
</gallery>
 +
 +
====GEANT Simulation (old) ====
 +
Pair Spectrometer's geometry implemented in the GEANT simulation.
 +
 +
[[Image:Pair_layout_tdr.jpg |350px]]
 +
 +
The top plot corresponds to the elevation and the bottom plot corresponds to the plan views.
 +
 +
-----
 +
Energy resolution of 24 FSF (top) and 6 WSF (bottom) counters estimated with
 +
the GEANT simulation. The converter thickness corresponds to <math> 5x10^{-3} X_0</math>.
 +
The contribution from the beam spot size (~ 4 mm at the converter) to the energy
 +
resolution dominates for the high-energy bins of the WSF counters.
 +
 +
[[Image:ps_count_res.jpg |250px]]
 +
 +
-----
 +
Photon energy spectrum measured by the pair spectrometer. The plot is obtained by
 +
requiring a coincidence between  the FSF and WSF counters and contains 24 x 6 = 144 energy
 +
bins. The coincident rate corresponds to a high-luminosity run
 +
( <math>10^8</math> photons/sec in the coherent peak ) using Aluminum converter with
 +
the thickness of <math>5 x 10^{-3}</math> radiation lengths.
 +
 +
[[Image:ps_rate.jpg |350px]]
 +
 +
=== TOSCA simulation ===
 +
 +
Pair Spectrometer TOSCA field maps, PS geometry *.opc and and TOSCA result *.op3 files can be found in /u/group/halld/Subsystems/PS/ directory.
 +
 +
Read readme.txt and summary.txt files for more details.
 +
  
 
=== Electronics ===
 
=== Electronics ===
 
[[Image:PS_Elect.png | 350px| Readout concept]]
 
[[Image:PS_Elect.png | 350px| Readout concept]]
  
[[Image:Pair_Readout.jpg |305px]]
+
[[Image:Pair_Readout.gif |750px]]
  
 
[[Media:Pair_Readout.pdf | Readout electronics]]
 
[[Media:Pair_Readout.pdf | Readout electronics]]
  
[[Image:Pair_trigger.jpg | 350px]]
+
[[Image:Pair_trigger.gif|750px]]
  
 
[[Media:Pair_trigger.pdf |Trigger electronics ]]
 
[[Media:Pair_trigger.pdf |Trigger electronics ]]
Line 50: Line 63:
 
<br />
 
<br />
 
----
 
----
 +
 +
=== Pair Spectrometer Converter ===
 +
[https://userweb.jlab.org/~vgr/SUPER%20HARP-November-2011/  Technical drawing of Super Harp ]
 +
 +
=== Old Design ===
  
 
== Links up ==
 
== Links up ==

Latest revision as of 11:24, 7 June 2018

Pair spectrometer overview

PairFig.jpg


18D36 magnet

GEANT Simulation (old)

Pair Spectrometer's geometry implemented in the GEANT simulation.

Pair layout tdr.jpg

The top plot corresponds to the elevation and the bottom plot corresponds to the plan views.


Energy resolution of 24 FSF (top) and 6 WSF (bottom) counters estimated with the GEANT simulation. The converter thickness corresponds to 5x10^{{-3}}X_{0}. The contribution from the beam spot size (~ 4 mm at the converter) to the energy resolution dominates for the high-energy bins of the WSF counters.

Ps count res.jpg


Photon energy spectrum measured by the pair spectrometer. The plot is obtained by requiring a coincidence between the FSF and WSF counters and contains 24 x 6 = 144 energy bins. The coincident rate corresponds to a high-luminosity run ( 10^{8} photons/sec in the coherent peak ) using Aluminum converter with the thickness of 5x10^{{-3}} radiation lengths.

Ps rate.jpg

TOSCA simulation

Pair Spectrometer TOSCA field maps, PS geometry *.opc and and TOSCA result *.op3 files can be found in /u/group/halld/Subsystems/PS/ directory.

Read readme.txt and summary.txt files for more details.


Electronics

Readout concept

Pair Readout.gif

Readout electronics

Pair trigger.gif

Trigger electronics


Pair Spectrometer Converter

Technical drawing of Super Harp

Old Design

Links up

Return to Photon Beam Main Page

Return to Hall-D WIKI main page