Difference between revisions of "Photon Beam Design Requirements"

From GlueXWiki
Jump to: navigation, search
(Global Specifications for the Hall D Photon Beam)
Line 1: Line 1:
''<u>Notice: this document is currently in draft form, and is expected to change over the coming weeks</u> - Richard Jones, 2/7/2008''
 
 
 
== Global Specifications for the Hall D Photon Beam ==
 
== Global Specifications for the Hall D Photon Beam ==
 
The following top-level specifications for the Hall D photon beam are determined by the physics requirements of the GlueX experiment and the anticipated capabilities of the CEBAF accelerator at 12 GeV.  The specifications for Hall D beamline components and related instrumentation are derived, in turn, from these.  References added to the end of each item in the list below indicate which subsystem is affected.
 
The following top-level specifications for the Hall D photon beam are determined by the physics requirements of the GlueX experiment and the anticipated capabilities of the CEBAF accelerator at 12 GeV.  The specifications for Hall D beamline components and related instrumentation are derived, in turn, from these.  References added to the end of each item in the list below indicate which subsystem is affected.
Line 11: Line 9:
 
# photon beam collimator with half-angle 22 &mu;r [4]
 
# photon beam collimator with half-angle 22 &mu;r [4]
 
# photon beam centered on collimator to within 3 &mu;r [1,4]
 
# photon beam centered on collimator to within 3 &mu;r [1,4]
# photons tagged with energy resolution better than 10 MeV within coherent peak [1,5,6]
+
# photons tagged with energy resolution better than 60 MeV within coherent peak [1,5,6]
 
# beam tagged with reduced resolution over extended range 3.0 - 11.7 GeV [5,7]
 
# beam tagged with reduced resolution over extended range 3.0 - 11.7 GeV [5,7]
 
# complete tagger coverage in range 9.0 - 11.7 GeV with energy resolution better than  20 MeV [5,7]
 
# complete tagger coverage in range 9.0 - 11.7 GeV with energy resolution better than  20 MeV [5,7]
# nominal operation at 10 MHz tagged photons in coherent peak after collimator [1,6]
+
# nominal operation at 100 MHz tagged photons in coherent peak after collimator [1,6]
 
# tagging rate 25 MHz within coherent peak at nominal intensity [6]
 
# tagging rate 25 MHz within coherent peak at nominal intensity [6]
 
# tagger capable of operating above nominal intensity, up to 100 MHz in coherent peak after collimator [1,5,6]
 
# tagger capable of operating above nominal intensity, up to 100 MHz in coherent peak after collimator [1,5,6]

Revision as of 06:07, 6 November 2008

Global Specifications for the Hall D Photon Beam

The following top-level specifications for the Hall D photon beam are determined by the physics requirements of the GlueX experiment and the anticipated capabilities of the CEBAF accelerator at 12 GeV. The specifications for Hall D beamline components and related instrumentation are derived, in turn, from these. References added to the end of each item in the list below indicate which subsystem is affected.

  1. choice of photon energy in the range 8 - 12 GeV [1]
  2. duty factor >90% at 500 MHz beam pulse repetition rate [1]
  3. orientable diamond crystal bremsstrahlung radiator [2,3]
  4. peak linear polarization of 40% at 9 GeV with collimation [2,3,4]
  5. average polarization 36% in coherent peak 8.4 - 9.0 GeV [2,3,4]
  6. photon beam collimator with half-angle 22 μr [4]
  7. photon beam centered on collimator to within 3 μr [1,4]
  8. photons tagged with energy resolution better than 60 MeV within coherent peak [1,5,6]
  9. beam tagged with reduced resolution over extended range 3.0 - 11.7 GeV [5,7]
  10. complete tagger coverage in range 9.0 - 11.7 GeV with energy resolution better than 20 MeV [5,7]
  11. nominal operation at 100 MHz tagged photons in coherent peak after collimator [1,6]
  12. tagging rate 25 MHz within coherent peak at nominal intensity [6]
  13. tagger capable of operating above nominal intensity, up to 100 MHz in coherent peak after collimator [1,5,6]
  14. beam adjustable down to threshold of 10-3 nominal intensity for absolute normalization measurements [1,8]
  15. average tagging efficiency at least 50% within coherent peak under nominal conditions, 70% for higher intensity running [1,5,6]
  16. continuous real-time monitoring of post-collimator beam spectrum [9,10]
  17. continuous real-time monitoring of the post-collimator beam intensity with an absolute accuracy 1%.
  18. average polarization within coherent peak determined with accuracy ±1% absolute [9,10]
  19. absolute tagged photon energy calibration better than ±10 MeV [9,10]
  20. post-collimated beam shielding sufficient to keep detector backgrounds originating outside the experimental target below 1% of those coming from the target seen by all detectors, for each significant particle species considered separately [11]

Photon Beam Subsystems

  1. 12 GeV electron beam and associated instrumentation
  2. diamond crystal radiator
  3. goniometer mount for radiators
  4. active photon collimator system
  5. tagging magnetic spectrometer
  6. high-resolution tagging microscope
  7. broad-band tagging hodoscope
  8. total absorption counter
  9. pair spectrometer and target
  10. pair spectrometer hodoscopes
  11. post-collimator beamline and shielding