Photon Beam Design Requirements

From GlueXWiki
Revision as of 17:37, 29 January 2008 by Jonesrt (Talk | contribs) (Global Specifications for the Hall D Photon Beam)

Jump to: navigation, search

Global Specifications for the Hall D Photon Beam

The following top-level specifications for the Hall D photon beam are determined by the physics requirements of the GlueX experiment and the capabilities of the CEBAF accelerator upgraded 12 GeV. The specifications for Hall D beamline components and related instrumentation are derived, in turn, from these. References added to the end of each item in the list below indicate which subsystem is affected.

  1. choice of photon energy in the range 8 - 12 GeV [1]
  2. duty factor >90% at 500 MHz beam pulse repetition rate [1]
  3. orientable diamond crystal bremsstrahlung radiator [2]
  4. peak linear polarization of 40% at 9 GeV with collimation [2,3]
  5. average polarization 36% in coherent peak 8.4 - 9.0 GeV [2,3]
  6. photon beam collimator with half-angle 22 μr [3]
  7. photon beam centered on collimator to within 3 μr [3]
  8. photons tagged with energy resolution better than 60 MeV (0.5%) within coherent peak [1,4,5]
  9. beam tagged with reduced resolution over extended range 3.0 - 11.4 GeV [4,6]
  10. complete tagger coverage in range 9.0 - 11.4 GeV with 1% resolution [6]
  11. absolute photon energy calibration better than ±30 MeV
  12. nominal operation at 10 MHz tagged photons in coherent peak after collimator [1,3]
  13. tagging rate 25 MHz within coherent peak at nominal intensity [5]
  14. tagger capable of operating at intensities up to 100 MHz in coherent peak after collimator [1,3,5]
  15. beam adjustable down to threshold of 10-4 nominal intensity for absolute normalization [6]
  16. average tagging efficiency at least 50% within coherent peak under nominal conditions [3,4]
  17. continuous real-time monitoring of post-collimator beam spectrum [7]
  18. average polarization within coherent peak determined with accuracy ±2% absolute [7]