Difference between revisions of "Photon flux for GlueX empty target runs"

From GlueXWiki
Jump to: navigation, search
 
(11 intermediate revisions by the same user not shown)
Line 11: Line 11:
 
|  
 
|  
 
| 6.93
 
| 6.93
|  Amorphous
+
|  Amorphous (Ebeam = 11.6 GeV)
 
|-
 
|-
 
| 51013
 
| 51013
 +
| (file 12 corrupted, excluded)
 +
| 5.78
 
|  
 
|  
| 5.78
 
|
 
 
|-
 
|-
 
| 51012
 
| 51012
Line 44: Line 44:
 
|-
 
|-
 
| 42339
 
| 42339
|  
+
| (file 13 corrupted, excluded)
 
| 7.74
 
| 7.74
 
|  Coherent bremsstrahlung
 
|  Coherent bremsstrahlung
Line 126: Line 126:
  
  
Photon flux for PrimEx empty target runs can be found below:
 
  
  
 +
'''The integrated photon flux for PrimEx empty target runs (Ebeam > 8 GeV)  can be found below (see at the end of this file):'''
  
Flux numbers are stored in CCDB tables:
+
: https://halldweb.jlab.org/primexd/data_quality_2019/quality_check_2019.pdf
 +
 
 +
 
 +
'''Flux numbers are stored in CCDB tables:'''
 
   
 
   
  
 
(the same tables, which we use for PrimEx:  
 
(the same tables, which we use for PrimEx:  
 +
 
/PHOTON_BEAM/pair_spectrometer/lumi/tagh_tagged
 
/PHOTON_BEAM/pair_spectrometer/lumi/tagh_tagged
 +
 
/PHOTON_BEAM/pair_spectrometer/lumi/tagm_tagged )
 
/PHOTON_BEAM/pair_spectrometer/lumi/tagm_tagged )
  
  
  
Run 30949
+
''' Example of data quality (runs with poor calibration)'''
 +
 
 +
 
 +
 
 +
Run 30949 (global time shift of the TAGM)
 
[[File:30949 bunch.png | Run30949 | 200 px]]
 
[[File:30949 bunch.png | Run30949 | 200 px]]
  

Latest revision as of 16:05, 18 March 2021


Run Number Data quality (calibration) N(photons) > 8 GeV, 10^9 photons Comments
51556 6.93 Amorphous (Ebeam = 11.6 GeV)
51013 (file 12 corrupted, excluded) 5.78
51012 8.92
51011 3.73
50766 5.14


Run Number Data quality (calibration) N(photons) > 8 GeV, 10^9 photons Comments
42339 (file 13 corrupted, excluded) 7.74 Coherent bremsstrahlung
41972 Bad tagh timing (97.23 the largest run )
41615 2.30
41386 15.55
41155 Bad timing
40903 Bad tagh timing



Run Number Data quality (calibration) N(photons) > 8 GeV Comments
30333 3.78 Coherent bremsstrahlung
30334 Bad tagm timing
30335 1.04
30336 Bad tagm timing
30337 5.32
30564 Bad tagm timing
30728 Bad tagm timing
30949 Bad tagm timing



The integrated photon flux for PrimEx empty target runs (Ebeam > 8 GeV) can be found below (see at the end of this file):

https://halldweb.jlab.org/primexd/data_quality_2019/quality_check_2019.pdf


Flux numbers are stored in CCDB tables:


(the same tables, which we use for PrimEx:

/PHOTON_BEAM/pair_spectrometer/lumi/tagh_tagged

/PHOTON_BEAM/pair_spectrometer/lumi/tagm_tagged )


Example of data quality (runs with poor calibration)


Run 30949 (global time shift of the TAGM) Run30949

Run 30334 (RF all counters) Run 30334

Run 30334 (TAGM time) Run 30334 (TAGM)

Run 40903 (TAGH time) Run 40903 (TAGH)