Difference between revisions of "Premixed 50/50"

From GlueXWiki
Jump to: navigation, search
Line 1: Line 1:
<P>
+
Pre-mixed 50/50 Ar/CO<sub>2</sub><br>
 
+
 
+
<br>
+
<br>
+
 
+
<br>
+
 
Cosmics
 
Cosmics
 
<br>
 
<br>
Line 19: Line 13:
 
{| border="1" cellpadding="2"
 
{| border="1" cellpadding="2"
 
|width="415pt"|[[Image:tracked_and_untracked_energy_2050V_old_preamp.jpg|thumb|none|400px|Yves's old preamp months ago, cosmics, 50/50 Ar/CO2, 2050V]]
 
|width="415pt"|[[Image:tracked_and_untracked_energy_2050V_old_preamp.jpg|thumb|none|400px|Yves's old preamp months ago, cosmics, 50/50 Ar/CO2, 2050V]]
|width="415pt"|[[Image:tracked_and_untracked_energy_2050V_new_preamp_premix.jpg|thumb|none|400px|Naomi's preamp, cosmics, 50/50 Ar/CO2 pre-mixed, 2050V]]
+
|width="415pt"|[[Image:tracked_and_untracked_energy_2050V_new_preamp_premix.jpg|thumb|none|400px|Naomi's new preamp, cosmics, 50/50 Ar/CO2 pre-mixed, 2050V]]
 
|}
 
|}
  
 
<p>
 
<p>
still have to get pics from Fe55 run at 2100V with new preamp </p>
+
Fe55 run at 2100V with new preamp saturates fADC which is on half range</p>
  
 
2100V - Fe55 - amplitude, old preamp, 2009 (left)  
 
2100V - Fe55 - amplitude, old preamp, 2009 (left)  
 
{| border="1" cellpadding="2"
 
{| border="1" cellpadding="2"
|width="415pt"|[[Image:Fe_amplitude_2100V_old_preamp_30599.jpg|thumb|none|400px|amplitude: Yves' old preamp months ago, 55Fe, 50/50 Ar/CO2, 2100V, 2009]]
+
|width="415pt"|[[Image:Fe_amplitude_2100V_old_preamp_30599.jpg|thumb|none|400px|amplitude: Yves's old preamp months ago, 55Fe, 50/50 Ar/CO2, 2100V, 2009]]
 +
|width="415pt"|[[Image:Fe_amplitude_2100V_new_preamp_30941.jpg|thumb|none|400px|amplitude: Naomi's new preamp, 55Fe, 50/50 Ar/CO2 pre-mixed, 2100V]]
 
|}
 
|}
  
 
2100V - Fe55 - energy, old preamp, 2009 (left) and 2010 (right)  
 
2100V - Fe55 - energy, old preamp, 2009 (left) and 2010 (right)  
 
{| border="1" cellpadding="2"
 
{| border="1" cellpadding="2"
|width="415pt"|[[Image:Fe_energy_2100V_old_preamp_30599.jpg|thumb|none|400px|energy: Yves' old preamp months ago, 55Fe, 50/50 Ar/CO2, 2100V, 2009]]
+
|width="415pt"|[[Image:Fe_energy_2100V_old_preamp_30599.jpg|thumb|none|400px|energy: Yves' old preamp months ago, 55Fe, 50/50 Ar/CO2, 2100V, 2009
 +
|width="415pt"|[[Image:Fe_energy_2100V_new_preamp_30941.jpg|thumb|none|400px|energy: Naomi's new preamp, 55Fe, 50/50 Ar/CO2 pre-mixed, 2100V]]
 
|}
 
|}

Revision as of 15:29, 5 August 2010

Pre-mixed 50/50 Ar/CO2
Cosmics

2050V - cosmics - amplitude, old preamp, 2009 (left)

Yves's old preamp months ago, cosmics, 50/50 Ar/CO2, 2050V
Naomi's preamp, cosmics, 50/50 Ar/CO2 pre-mixed, 2050V


2050V - cosmics - energy, old preamp (left) and new preamp (right)

Yves's old preamp months ago, cosmics, 50/50 Ar/CO2, 2050V
Naomi's new preamp, cosmics, 50/50 Ar/CO2 pre-mixed, 2050V

Fe55 run at 2100V with new preamp saturates fADC which is on half range

2100V - Fe55 - amplitude, old preamp, 2009 (left)

amplitude: Yves's old preamp months ago, 55Fe, 50/50 Ar/CO2, 2100V, 2009
amplitude: Naomi's new preamp, 55Fe, 50/50 Ar/CO2 pre-mixed, 2100V

2100V - Fe55 - energy, old preamp, 2009 (left) and 2010 (right)

[[Image:Fe_energy_2100V_old_preamp_30599.jpg|thumb|none|400px|energy: Yves' old preamp months ago, 55Fe, 50/50 Ar/CO2, 2100V, 2009
energy: Naomi's new preamp, 55Fe, 50/50 Ar/CO2 pre-mixed, 2100V