Private:UConn test setup

From GlueXWiki
Revision as of 11:27, 24 September 2012 by Somov (Talk | contribs)

Jump to: navigation, search

Boards in the crate

Board Slot Serial
CPU (halldtrg5) 1
TI (Old) 2
FADC250 5 B21595_06R
SDC 9
LE discriminator 14 C_15
F1TDC 16


Front pannel connections

From To
External trigger TI input, IN1
L1 Accept ( 3rd from the bottom ) SDC TRG
L1 Accept ( 4 th from the bottom ) F1TDC TRG
TI Out0 F1TDC SYNC


Setting up the setup

  • Connect keybord and monitor (if needed) to the Intel ROC.
  • Connect Ethernet cable to the upper ROC LAN connector.
  • Change ROC IP address (you will see the MAC address when you start booting the controller)
  • Login under halld

Directories

Most DAQ files (CODA), the Run Control and other applications have been installed localy on the ROC flash disc. You will need to mount the remote data disc to store data files.

Below is a description of some directories.

  • The home directory is /home/halld
  • /home/halld/micro/rol contains the F1TDC configuration file and the link to the DAC readout list (see descriptions below)
  • /home/halld/micro/coda contains Run Control data base
  • /home/halld/data is a directory for the DAQ data storage. The external drive has to be mounted to here
  • /home/halld/micro/coda_micro_setup is a script with configuration variables
    • you have to edit this file ad change some variables if needed
    • source coda_micro_setup to set variables up

How to run DAQ

Change electronics boards initialization parameters