Difference between revisions of "RCDB Conditions Help"

From GlueXWiki
Jump to: navigation, search
(Created page with " {| class="wikitable" ! Condition Name !! EPICS variable !! Notes |- | beam_current || IBCAD00CRCUR6 || Beam current from electron dump (?) BCM, averaged over run, in nA |-...")
 
Line 1: Line 1:
 
+
This page gives definitions of the condition variables stored in the RCDB as of RunPeriod-2016-02.
  
 
{| class="wikitable"
 
{| class="wikitable"
Line 14: Line 14:
 
| luminosity || N/A || For future use
 
| luminosity || N/A || For future use
 
|-
 
|-
| ps_converter || hd:converter_at_[home,a,b,c] || 5x10<sup>-3</sup> RL, 1x10<sup>-3</sup> RL, 3x10<sup>-4</sup> RL, Retracted
+
| ps_converter || hd:converter_at_[home,a,b,c] || 5 x 10<sup>-3</sup> RL, 1 x 10<sup>-3</sup> RL, 3 x 10<sup>-4</sup> RL, Retracted
 
|-
 
|-
 
| solenoid_current || HallD-PXI:Data:I_Shunt || Measured current in solenoid magnet, in A
 
| solenoid_current || HallD-PXI:Data:I_Shunt || Measured current in solenoid magnet, in A
Line 20: Line 20:
 
| status || N/A || For future use
 
| status || N/A || For future use
 
|-
 
|-
| radiator_index || HD:GONI:RADIATOR_INDEX || Goniometer radiator position index, as described [https://halldsvn.jlab.org/repos/trunk/controls/epics/app/goniApp/Db/goni.substitutions|in this page].
+
| radiator_index || HD:GONI:RADIATOR_INDEX || Goniometer radiator position index, as described [https://halldsvn.jlab.org/repos/trunk/controls/epics/app/goniApp/Db/goni.substitutions in this page].
 
|-
 
|-
| radiator_id || HD:GONI:RADIATOR_ID || Goniometer radiator unique ID, as described [https://halldsvn.jlab.org/repos/trunk/controls/epics/app/goniApp/Db/goni.substitutions|in this page].
+
| radiator_id || HD:GONI:RADIATOR_ID || Goniometer radiator unique ID, as described [https://halldsvn.jlab.org/repos/trunk/controls/epics/app/goniApp/Db/goni.substitutions in this page].
 
|-
 
|-
 
| polarization_direction || HD:CBREM:PLANE || Direction of the photon beam linear polarization with respect to the floor: PARA, PERP, or UNKNOWN
 
| polarization_direction || HD:CBREM:PLANE || Direction of the photon beam linear polarization with respect to the floor: PARA, PERP, or UNKNOWN
 
|-
 
|-
| radiator_type || Goniometer radiator name, as described [https://halldsvn.jlab.org/repos/trunk/controls/epics/app/goniApp/Db/goni.substitutions|in this page], Amorphous radiator (2x10<sup>-5</sup> RL, 1x10<sup>-4</sup> RL, 3x10<sup>-4</sup> RL), or retracted
+
| radiator_type || HD:GONI:RADIATOR_NAME OR hd:radiator_at_[a,b,c] || Goniometer radiator name, as described [https://halldsvn.jlab.org/repos/trunk/controls/epics/app/goniApp/Db/goni.substitutions in this page], Amorphous radiator (2 x 10<sup>-5</sup> RL, 1 x 10<sup>-4</sup> RL, 3 x 10<sup>-4</sup> RL), or retracted
 
|-
 
|-
 
| target_type || HLD:TGT:status || Status of LH2 target: OFF, Cooling, Filling, FULL & Ready, Emptying, EMPTY & Ready
 
| target_type || HLD:TGT:status || Status of LH2 target: OFF, Cooling, Filling, FULL & Ready, Emptying, EMPTY & Ready

Revision as of 01:33, 9 February 2016

This page gives definitions of the condition variables stored in the RCDB as of RunPeriod-2016-02.

Condition Name EPICS variable Notes
beam_current IBCAD00CRCUR6 Beam current from electron dump (?) BCM, averaged over run, in nA
beam_energy HALLD:p Measured electron beam energy, in GeV
coherent_peak HD:CBREM:REQ_EDGE Requested high-energy edge of the coherent peak, in GeV
collimator_diameter hd:collimator_at_[block,a,b] 5 mm, 3.4 mm, blocking
luminosity N/A For future use
ps_converter hd:converter_at_[home,a,b,c] 5 x 10-3 RL, 1 x 10-3 RL, 3 x 10-4 RL, Retracted
solenoid_current HallD-PXI:Data:I_Shunt Measured current in solenoid magnet, in A
status N/A For future use
radiator_index HD:GONI:RADIATOR_INDEX Goniometer radiator position index, as described in this page.
radiator_id HD:GONI:RADIATOR_ID Goniometer radiator unique ID, as described in this page.
polarization_direction HD:CBREM:PLANE Direction of the photon beam linear polarization with respect to the floor: PARA, PERP, or UNKNOWN
radiator_type HD:GONI:RADIATOR_NAME OR hd:radiator_at_[a,b,c] Goniometer radiator name, as described in this page, Amorphous radiator (2 x 10-5 RL, 1 x 10-4 RL, 3 x 10-4 RL), or retracted
target_type HLD:TGT:status Status of LH2 target: OFF, Cooling, Filling, FULL & Ready, Emptying, EMPTY & Ready

Other Notes

  • When the nA BPMs are calibrated, we could use another variable for the beam current that might be more accurate for lower (<1 uA) currents, e.g. IPM5C11.VAL,IPM5C11A.VAL,IPM5C11B.VAL,IPM5C11C.VAL