FCAL HV scan:  
 
FCAL HV scan:  
* '''Blue LED 100Hz continuous 15V'''
+
* [https://halldweb.jlab.org/primexd/phase-II/FCAL-HV-scan/bias10V/ '''Blue LED 100Hz continuous 15V''']
 
**HV set to 1500V -> 80280
 
**HV set to 1500V -> 80280
 
**HV set to 1550V -> 80284
 
**HV set to 1550V -> 80284

Revision as of 16:42, 2 September 2021

Monitoring Team

Run list

FCAL HV scan:

  • Blue LED 100Hz continuous 15V
    • HV set to 1500V -> 80280
    • HV set to 1550V -> 80284
    • HV set to 1600V -> 80285
    • HV set to 1650V -> 80286
    • HV set to 1700V -> 80287
    • HV set to 1750V -> 80288
    • HV set to 1800V -> 80289
  • Blue LED 100Hz continuous 10V
    • HV set to 1800V -> 80290
    • HV set to 1750V -> 80292
    • HV set to 1700V -> 80293
    • HV set to 1650V -> 80294
    • HV set to 1600V -> 80295
    • HV set to 1550V -> 80296
    • HV set to 1500V -> 80297