Difference between revisions of "RunPeriod-2021-09 Validation"

From GlueXWiki
Jump to: navigation, search
(FCAL energy Calibration)
(Batch 1)
Line 91: Line 91:
  
 
== Batch 1 ==
 
== Batch 1 ==
''' Runs 81113 - 81267 '''
+
''' Runs 81113 - 81267, periods 1-4 '''
  
 
'''Detector systems used are FCAL,TAGM,TAGH,CCAL,BCAL,PS. No Magnetic field. SC, CDC, FDC were not used '''
 
'''Detector systems used are FCAL,TAGM,TAGH,CCAL,BCAL,PS. No Magnetic field. SC, CDC, FDC were not used '''

Revision as of 15:41, 6 October 2021

Monitoring Team

Sasha: PS

Tyler: Tagger

Igal: FCAL

Drew: CCAL

Run list

  • period 1, 81113 -> 81120, 150 nA, Summer 2020 HV, FCAL pi0 with FDC & CDC turn off
  • period 2, 81126 -> 81164, 150 nA, Summer 2020 HV - 6V, FCAL pi0 with FDC & CDC turn off
  • period 3, 81221 -> 81123, 150 nA, Fall 2021 ver 1, FCAL pi0 with FDC & CDC turn off
  • period 4, 81262 -> 81267, 200 nA, Fall 2021 ver 2, FCAL pi0 with FDC & CDC turn off
  • period 5, 81331 -> 81342, 50 nA, Fall 2021 ver 2, low intensity Be production with FDC & CDC turn on
  • period 6, 81343 -> 81355, 50 nA, Fall 2021 ver 2, low intensity Be production with FDC & CDC turn on
  • period 7, 81356 -> 81373, 100 nA, Fall 2021 ver 2, medium intensity Be production with FDC & CDC turn off
  • period 8, 81374 -> 81381, 200 nA, Fall 2021 ver 2, Be production with FDC & CDC turn off
  • period 9, 81384 -> 81387, 200 nA, Fall 2021 ver 2, empty "Be" target with FDC & CDC turn off <= period8 cal
  • period 10, 81388 -> 81390, 100 nA, Fall 2021 ver 2, empty "Be" target with FDC & CDC turn off <= period8 cal
  • period 11, 81390 -> 81393, 50 nA, Fall 2021 ver 2, empty "Be" target with FDC & CDC turn off <= period8 cal
  • period 12, 81397 -> 81399, 200 nA, Fall 2021 ver 2, empty "hot" He cell target with FDC & CDC turn off <= period8 cal
  • period 13, 81401 -> 81403, 100 nA, Fall 2021 ver 2, empty "cold" He cell target with FDC & CDC turn off <= period8 cal

Periods 1 to 3 are calibration runs. Physics run starts at period 4.

So far 4.03B events have been taken

https://docs.google.com/spreadsheets/d/1AkIFVa5aicJvT4a02rlCaFqTFhIOfWjBej666OyRZLo/edit#gid=678404295

Note on monitoring launches

https://docs.google.com/spreadsheets/d/1cvoK23aw9XGVM8_xkTNZxUuJ7k0iWPrsHGMbhulPM1o/edit#gid=1665922131

PS Calibration

Tagger Calibration

FCAL Calibration

  1. Lists of PMT and base replaced
  2. FCAL HV scan
  3. FCAL HV tuning
  4. FCAL energy calibration

CCAL Calibration

2021 Run List

Run Lists

AMO 81113,81114,81118,81119,81120,81126,81127,81128,81129,81130,81131,81132,81133,81134,81159,81164,81221,81222,81223,81261,81262,81263,81264,81265,81266,81267

Monitoring Launch Checks

Team members

  • BCAL: Tolga Erbora, Zisis Papandreou/Regina
  • CDC: Naomi Jarvis/CMU, Jason Barlow
  • FCAL: Susan Schadmand
  • CCAL: ?
  • FDC: Churamani Paudel
  • PS/PSC: Susan Schadmand
  • TAGH/TAGM: Gabriel Rodriguez
  • TOF: Edmundo Barriga
  • SC: Rupesh Dotel
  • Timing: Mariana Khachatryan
  • Analysis: Lawrence Ng


Detector/Calibration Experts

  • BCAL: Mark Dalton, Zisis Papandreou, Elton Smith
  • CDC: Naomi Jarvis, Beni Zihlmann
  • FCAL: Mark Dalton, Malte Albrecht, Rebecca Barsotti, Igal Jaegle
  • CCAL: Alex Somov, Drew Smith
  • FDC: Lubomir Pentchev
  • PS/PSC: Alex Somov, Olga Cortes
  • TAGH: Alex Somov, Olga Cortes
  • TAGM: Richard Jones
  • TOF: Paul Eugenio, Beni Zhilmann
  • SC: Mark Ito
  • Timing: Sean Dobbs
  • Analysis: Alexander Austregesilo, Sean Dobbs

Batch 1

Runs 81113 - 81267, periods 1-4

Detector systems used are FCAL,TAGM,TAGH,CCAL,BCAL,PS. No Magnetic field. SC, CDC, FDC were not used


Notes