Difference between revisions of "Run Planning Meeting Notes, Nov 8-Nov 14, 2018"

From GlueXWiki
Jump to: navigation, search
(Thursday, Nov 8 at 08:45)
(Thursday, Nov 8 at 08:45)
Line 24: Line 24:
 
#* beam position went awry, rates soared, reference module for IOC reading out 5C11B failed, replaced
 
#* beam position went awry, rates soared, reference module for IOC reading out 5C11B failed, replaced
 
#* EPICS froze for 2h, started working without intervention, now again unresponsive
 
#* EPICS froze for 2h, started working without intervention, now again unresponsive
#* [https://logbooks.jlab.org/entry/3622585 Target PTR turned off]
+
#* [https://logbooks.jlab.org/entry/3622585 Target PTR turned off], alarm ignored
 
#Reports
 
#Reports
 
#* [https://logbooks.jlab.org/entry/3622942 Monitoring]
 
#* [https://logbooks.jlab.org/entry/3622942 Monitoring]
 
# Plans
 
# Plans
 
#Notes
 
#Notes

Revision as of 10:22, 8 November 2018

<- Back to Run Coordination Meetings:Fall2018 Run

Thursday, Nov 8 at 08:45

  1. Last 24h:
  2. Issues
    • PS and PSC coincidence scalers frozen, ps_client running on gluon100 restarted, instructions in hdops wiki
    • beam position went awry, rates soared, reference module for IOC reading out 5C11B failed, replaced
    • EPICS froze for 2h, started working without intervention, now again unresponsive
    • Target PTR turned off, alarm ignored
  3. Reports
  4. Plans
  5. Notes