Difference between revisions of "Run Planning Meeting Notes, September 3 - 9, 2020"

From GlueXWiki
Jump to: navigation, search
(Thursday, September 3)
Line 19: Line 19:
 
#* Start to take data at 10:15 pm
 
#* Start to take data at 10:15 pm
 
#* [https://logbooks.jlab.org/entry/3839417 Good data taking started at 4:00 am]
 
#* [https://logbooks.jlab.org/entry/3839417 Good data taking started at 4:00 am]
# Report/issues:
+
# Reports/issues:
 
#* [https://logbooks.jlab.org/entry/3839239 DAQ issues], random pulser was left on from the CPP run yesterday morning, which was swamping the DAQ with too many triggers
 
#* [https://logbooks.jlab.org/entry/3839239 DAQ issues], random pulser was left on from the CPP run yesterday morning, which was swamping the DAQ with too many triggers
 
#* [https://logbooks.jlab.org/entry/3839413 Solenoid alarms for mass flow and diff temp]
 
#* [https://logbooks.jlab.org/entry/3839413 Solenoid alarms for mass flow and diff temp]

Revision as of 13:06, 2 September 2020

<- Back to Run Coordination Meetings:Summer2020

Integrated trigger count

GlueX Statistics Run Sheet


MEDCON 5 restrictions (Bob May email)

  1. adhere to counting room capacity restrictions
  2. maintain 6 ft. separation (briefly passing another person inside 6 ft. while moving about the counting room is inevitable and is OK)
  3. wear masks anytime more than one person present in the counting room
  4. at MEDCON 5 the lab has no cafeteria services because eating "cafeteria style" (eating in common from prepared food) is inconsistent with COVID-19 controls. Staging food in the counting room to share is inconsistent with MEDCON 5 COVID-19 controls.
  5. food and drink consumption - because it requires removing face coverings to consume - should be limited to packaged food and drink brought for personal use that is consumed while maintaining at least 6 ft. from the nearest person and ideally, consumed in a separate room from others.

Thursday, September 3

  1. Last 24 hours:
  2. Reports/issues:
  3. Pending issues:
    • TAGM missing channels due to preamp (Nick, Richard). Update
  4. Run plan
    • Ramping up magnet at 10 am
    • Diamond 0/90 PARA
      • 2 hours: focused FCAL trigger in GEM location (FCAL_TRACK_CENT_m9.conf)
      • 8 hours: standard FCAL-BCAL trigger at 150 nA (low energy TAGH turned on)
      • 4 hours: standard FCAL-BCAL trigger at 250 nA (low energy TAGH turned off)
      • 4 hours: standard FCAL-BCAL trigger at 350 nA (low energy TAGH turned off)