Difference between revisions of "Run Table"

From GlueXWiki
Jump to: navigation, search
Line 1: Line 1:
<table cellpadding=2 cellspacing=2 border=2>
+
<pre>
<tr>
+
                                                <-      BCAL        ->
<th>Run Number</th><th>Date/Time</th><th>Configuration</th><th colspan=2>BCAL ok?</th><th>Tagger ok?</th><th>Trigger ok?</th><th>Comments</th>
+
Run No Date Time Curr. Config.  Trigger Tagger ADC  TDC  Cell-3  Cell-8 Comments
</tr>
+
3000  Sep24 13:40  5  Rotation  ok     ok   ok  ok  22000  2500    Beam unstable
<tr>
+
 
<th>&nbsp;</th><th>&nbsp;</th><th>&nbsp;</th><th>ADC</th><th>TDC</th><th>&nbsp;</th>
+
</pre>
  <th>&nbsp;</th><th>&nbsp;</th>
+
 
</tr>
+
 
<tr>
+
* ''Configuration'' are reflected in the [http://www.jlab.org/Hall-D/software/wiki/index.php/Beam_Test_Run_Plan#Run_Table Run Plan]:
<td align=center>&nbsp;</td><td align=center>&nbsp;</td><td align=center>&nbsp;</td><td align=center>&nbsp;</td><td align=center>&nbsp;</td><td align=center>&nbsp;</td><td align=right>&nbsp;</td><td>&nbsp;</td>
+
**Commissioning
</tr>
+
**Rotation (platform, at 90 degrees, center of BCAL), Length (platform, at 90 degrees, length scan)
<tr>
+
**Height (platform, at 90 degrees, up/down scan)
<td align=center>&nbsp;</td><td align=center>&nbsp;</td><td align=center>&nbsp;</td><td align=center>&nbsp;</td><td align=center>&nbsp;</td><td align=center>&nbsp;</td><td align=right>&nbsp;</td><td>&nbsp;</td>
+
**Pre-radiator (platform, at 90 degrees, center of BCAL)
</tr>
+
**Steep (alcove, at 10-50 degrees, at lengths intercepting full depth of BCAL)
</table>
+
**Grazing (alcove, at 10-25 degrees, at lengths allowing showers to leak out of end of BCAL)
 +
**Current (platform, at 90 degrees, beam current study)
 +
**Trigger (platform, at 90 degrees, trigger studies)
 +
* Trigger, Tagger, BCAL-ADC, BCAL-TDC columns require checking ALL the spectra in the ROOT histos.
 +
* The ''Cell'' column reflects the number of counts/entries in the ANDed (North AND South) cell ADC spectrum.  This provide a rough indication of hits on the particular cell.

Revision as of 11:55, 24 September 2006

                                                 <-       BCAL         ->
Run No Date  Time  Curr. Config.  Trigger Tagger ADC  TDC  Cell-3  Cell-8 Comments
 3000  Sep24 13:40   5   Rotation   ok      ok    ok   ok   22000   2500    Beam unstable


  • Configuration are reflected in the Run Plan:
    • Commissioning
    • Rotation (platform, at 90 degrees, center of BCAL), Length (platform, at 90 degrees, length scan)
    • Height (platform, at 90 degrees, up/down scan)
    • Pre-radiator (platform, at 90 degrees, center of BCAL)
    • Steep (alcove, at 10-50 degrees, at lengths intercepting full depth of BCAL)
    • Grazing (alcove, at 10-25 degrees, at lengths allowing showers to leak out of end of BCAL)
    • Current (platform, at 90 degrees, beam current study)
    • Trigger (platform, at 90 degrees, trigger studies)
  • Trigger, Tagger, BCAL-ADC, BCAL-TDC columns require checking ALL the spectra in the ROOT histos.
  • The Cell column reflects the number of counts/entries in the ANDed (North AND South) cell ADC spectrum. This provide a rough indication of hits on the particular cell.