Difference between revisions of "Semi-Automatic Field Mapping Logger"
From GlueXWiki
(→Running the Field Logger Software) |
m (→Running the Field Logger Software) |
||
Line 9: | Line 9: | ||
# Choose the type of file operation (default: open or create) | # Choose the type of file operation (default: open or create) | ||
# Open or Create a data file | # Open or Create a data file | ||
− | # Load the appropriate Z preset file | + | # Type in the radius and phi angle of current probe position |
+ | # Load the appropriate Z preset file corresponding to current radius | ||
# Use '''Previous''' and '''Next''' to choose the starting Z position if needed | # Use '''Previous''' and '''Next''' to choose the starting Z position if needed | ||
# Move and turn the probes to desired Z position with a very small incline angle (both readings should be in green) | # Move and turn the probes to desired Z position with a very small incline angle (both readings should be in green) |
Revision as of 19:35, 19 June 2013
Field Mapping System Diagram
Running the Field Logger Software
1. Use remote desktop to log onto halld2 using account 'JLAB\halldusers', ask Elliott for password
rdesktop halld2 -g 1800x1000
2. Double click the shortcut Field_Logger on the desktop to run the LabVIEW application
- Verify that all readings are updating
- Choose the type of file operation (default: open or create)
- Open or Create a data file
- Type in the radius and phi angle of current probe position
- Load the appropriate Z preset file corresponding to current radius
- Use Previous and Next to choose the starting Z position if needed
- Move and turn the probes to desired Z position with a very small incline angle (both readings should be in green)
- Click Record to record current readings
- Continue to next point
Files
The files are stored on the halld-online group disk here:
/group/halld-online/Solenoid_Mapping
Which should also be accessible from the "M:" drive
The file names are formatted to contain the date, start time, phi value, and radius. For example, the following file was:
- created on May 1st, 2013 at 11:39am
- the strut was positioned such that the tube positions were along φ=90o
- tube was at R=0 (i.e. along the center of the magnet).
Field_Data_20130501_1139_P90_R12.dat
The columns of a data file are: radius(inch), phi(deg), Z(cm), Incline(deg), B_x(Gauss), B_y(Gauss), B_z(Gauss) and B_axial(Gauss). And the X,Y,Z direction are defined as
- X: points to the beam left
- Y: points vertically up
- Z: points to the beam dump