Line 4: Line 4:
 
#* assume that 2000 photons are collected (20 % light collection efficiency)
 
#* assume that 2000 photons are collected (20 % light collection efficiency)
 
#* 400 p.e. (assuming 20% quantum efficiency)
 
#* 400 p.e. (assuming 20% quantum efficiency)
 +
  
 
''' Counter rates (according to the latest Dan's design) '''
 
''' Counter rates (according to the latest Dan's design) '''
# 1.1 &mu; A electron current, <math>10^{-4} X_{0}</math> radiator  
+
* 1.1 &mu; A electron current, <math>10^{-4} X_{0}</math> radiator  
 
(corresponds to the photon flux of <math>5x10^{7}</math> phot/sec in the cohrent peak region)
 
(corresponds to the photon flux of <math>5x10^{7}</math> phot/sec in the cohrent peak region)
# Counter rate around E_gamma = 9 GeV: 1 - 1.5 MHz  
+
* Counter rate around E_gamma = 9 GeV: '''1 - 1.5 MHz''' 
(counter withd 20 MeV)
+
(counter with ~20 MeV)

Revision as of 15:43, 14 September 2012

Light yield estimates

  1. 5 mm thick scintillators
  2. 10000 initial photons per tagged electron
    • assume that 2000 photons are collected (20 % light collection efficiency)
    • 400 p.e. (assuming 20% quantum efficiency)


Counter rates (according to the latest Dan's design)

  • 1.1 μ A electron current, 10^{{-4}}X_{{0}} radiator

(corresponds to the photon flux of 5x10^{{7}} phot/sec in the cohrent peak region)

  • Counter rate around E_gamma = 9 GeV: 1 - 1.5 MHz

(counter with ~20 MeV)