File list

From GlueXWiki
Jump to: navigation, search

This special page shows all uploaded files.

File list
 
First page
Previous page
Last page
Date Name Thumbnail Size Description Versions
10:43, 28 August 2008 Sr90 collimation.gif (file) 2 KB schematic view of the collimator for the Sr90 source. The 1mm x 1mm groove is used to fix the scintillation fiber in place. The actual collimation is done by a slit that runs parallel to the groove and is 5mm long with a width of 0.5mm (half the width of 1
11:01, 17 March 2010 Halld gas systemA.pdf (file) 3 KB   1
08:51, 18 March 2011 Tof lightguide bend1.pdf (file) 3 KB geometrical test of required bend for a 200mm light guide to accommodate a 66mm outer diameter PMT with shielding. 1
08:35, 18 March 2011 Tof paddle setting.pdf (file) 3 KB space available at the end of the tof paddle with 66mm diameter PMT plus shielding the read line indicates the maximum impact angle tracks can have. 1
09:25, 18 March 2011 Tof lightguide bend10deg.pdf (file) 3 KB light guide with 10degree bend in the 110mm section that tapers from rectangular to round cross section for 60mm high paddles 1
09:27, 18 March 2011 Tof lightguide bend16deg.pdf (file) 3 KB The 110 mm long tapered section from rectangular cross section to round cross section with a 16 degree bend to provide enough space for the PMT plus shielding for 30mm high paddles. 1
11:01, 17 March 2010 Halld gas systemB.pdf (file) 4 KB   1
07:46, 31 May 2016 T offset c17.gif (file) 4 KB   1
09:18, 18 March 2011 Tof lightguide20cm.pdf (file) 4 KB a 200mm long light guide that tapers over 110mm from square cross section to circular cross section. 1
09:30, 7 December 2022 Ctof triggers.gif (file) 5 KB events with CTOF trigger only compared to COTF trigger with other triggers as well 1
10:05, 9 August 2016 Tofres run11666.gif (file) 5 KB   1
19:29, 7 December 2011 Gain PMT VA0009.gif (file) 5 KB   1
07:47, 31 May 2016 T offset c22.gif (file) 5 KB   1
10:05, 9 August 2016 Tofres 1500V.gif (file) 5 KB   1
10:04, 9 August 2016 Tofres 1200V.gif (file) 6 KB mean time difference paddle 21 of both planes 1
09:18, 24 March 2009 Led linearity test2a.gif (file) 6 KB linearity test of the extracted mean number of photo electrons from the XP1911 PMT used in the fiber test. The light output from the led is monitored by an XP2020 PMT plotted on the horizontal axis. 1
16:33, 23 March 2009 Mnpe fiberscan.gif (file) 6 KB mean number of photo electrons for SCSF-78MJ fibers at 200cm from the PMT using a Sr90 source. 1
10:05, 9 August 2016 Tofres 1250V.gif (file) 6 KB mean time difference paddel 21 both planes 1
15:59, 15 April 2015 Deltat fitposition p18 example.gif (file) 7 KB   1
09:32, 2 April 2020 Sc dr ped.gif (file) 7 KB Start Counter Pedstal/Integral as a function of flux for the Primex and Fall19 running 1
15:49, 15 April 2015 Velocity example.gif (file) 7 KB   1
15:34, 15 April 2015 Meantime average to refpaddle example.gif (file) 7 KB   1
10:59, 3 February 2022 Sc darkratetest new.gif (file) 7 KB   1
12:14, 22 July 2010 Hit multiplicity photons plane0 and1.gif (file) 8 KB hit multiplicity of the TOF planes given an 1GeV photon passed throuth. 1
10:25, 15 September 2023 Sc adcresponse matchedHits R41835 and R90660 paddle3 NoseSection 7.gif (file) 8 KB   1
12:15, 22 July 2010 Hit multiplicity muons plane0 and1.gif (file) 8 KB hit multiplicity in the TOF planes given a 3GeV muon passed through. 1
15:26, 15 April 2015 Fit projection example2.gif (file) 8 KB   1
09:22, 16 August 2016 Paddle eff run8 ver2.gif (file) 8 KB   1
09:22, 16 August 2016 Paddle eff run15 ver2.gif (file) 8 KB   1
10:25, 15 September 2023 Sc adcresponse matchedHits R41835 and R90660 paddle3 NoseSection 15.gif (file) 8 KB   1
15:48, 15 April 2015 Deltat fitposition example.gif (file) 8 KB   1
15:49, 15 April 2015 Timediff planesymmetry example.gif (file) 8 KB   1
15:26, 15 April 2015 Fit projection example1.gif (file) 8 KB   1
11:49, 11 February 2016 Toomanywords.c (file) 8 KB   1
11:55, 17 July 2007 Flowchart.pdf (file) 9 KB   1
18:40, 24 March 2009 Scopeshot.gif (file) 9 KB scope shot of signals from the XP2020 PMT caused by light from an LED 1
09:23, 16 August 2016 Paddle eff run5 ver2.gif (file) 9 KB   1
07:49, 25 October 2023 Sc with KLF beam.gif (file) 9 KB   1
16:40, 23 March 2009 Atten mue.gif (file) 9 KB attenuation length and mean number of photo electrons for SCSF-78MJ fibers using a Sr90 source. 1
08:07, 25 March 2009 Scopeshot3.gif (file) 9 KB and another scope shot showing the signal from an XP2020 PMT for light from a blue LED 1
14:58, 6 July 2009 Top timediff position.gif (file) 9 KB similar to the time difference spectrum but using a mean light speed of 16cm/ns inside the scintillator paddle to calculate the impact position of the cosmic ray passing through the paddle. 1
14:53, 6 July 2009 Top timediff.gif (file) 9 KB Time difference spectrum of between left and right PMT of the first paddle in the TOP plane. f1TDC in high resolution mode is used. 1
19:15, 7 December 2011 Adc left.gif (file) 10 KB   1
09:23, 16 August 2016 Paddle eff run20 ver2.gif (file) 10 KB   1
10:26, 9 December 2011 Delta t tof 3.gif (file) 10 KB   1
10:27, 9 December 2011 Delta t tof 4.gif (file) 10 KB   1
15:16, 6 December 2011 Timediff bottrig.gif (file) 10 KB time difference of the bottom trigger paddle. the horizontal axis is in TDC channel units with 0.025ns per channel. 1
10:26, 9 December 2011 Delta t tof 1.gif (file) 10 KB   1
09:23, 16 August 2016 Paddle eff run21 ver2.gif (file) 10 KB   1
08:29, 21 July 2010 Plane0 hitdist 1gevphotons.gif (file) 10 KB hit distribution in plane 0 of the TOF with 100k photons of 1GeV generated at the target and thrown between 1 and 11 degree in theta. No energy threshold is applied. 1
First page
Previous page
Last page