(newest | oldest) View (newer 20 | older 20) (20 | 50 | 100 | 250 | 500)- 18:50, 2 July 2008 Zihlmann (Talk | contribs) uploaded File:Bcal 4x6.pdf (geometry file, implemenation of BCAL 4x6 inner readout)
- 14:55, 5 June 2008 Zihlmann (Talk | contribs) uploaded File:Gxroot.pdf (how to use the root geometry in DANA)
- 17:35, 5 February 2008 Zihlmann (Talk | contribs) uploaded File:Feu noise cwbase bestbase lowestnoise.jpg (CW-base with very low noise. Lowest noise of all bases that were looked at.)
- 15:09, 5 February 2008 Zihlmann (Talk | contribs) uploaded File:Feu noise cwbase.jpg (Signal and noise (scope shot) from one of the PMTs during the test to measure the temperature of the CW-Bases mounted in the platic block. The noise is from the base itself.)
- 15:06, 5 February 2008 Zihlmann (Talk | contribs) uploaded File:Feu signalB cwbase.jpg (Signal (cope shot) from one of the four PMTs when testing the temperature of the CW-base mounted in the plastic block.)
- 14:42, 5 February 2008 Zihlmann (Talk | contribs) uploaded File:Cosmics response LGwrapped.jpg (ADC spectrum of cosmic ray data. The PMT is coupled to the lead glass through a 3.7cm long light guide that was glued to the PMT with epoxy and attached to the lead glass with optical grease. The light guide is wrapped in aluminized mylar.)
- 14:40, 5 February 2008 Zihlmann (Talk | contribs) uploaded File:Cosmics response airgap.jpg
- 14:51, 29 January 2008 Zihlmann (Talk | contribs) uploaded File:Leadglass F8 atten bothpmts.jpg
- 19:50, 24 January 2008 Zihlmann (Talk | contribs) uploaded File:Tofres 550cm tof.jpg
- 11:02, 14 November 2007 Zihlmann (Talk | contribs) uploaded File:Surfaces.jpg (ligh guide test with mirroring the surface using aluminum vapor or just aluminized mylar.)
- 10:48, 14 November 2007 Zihlmann (Talk | contribs) uploaded File:Leadglass F8 atten pmt2.jpg (plot the ADC landau peak position (MPV) from the fit as a function of the position of the sctintillator trigger along the lead glass block. Then fit an exponential function of the form f(x)=a+exp(x/b) where b is the attenuation factor.)
- 10:44, 14 November 2007 Zihlmann (Talk | contribs) uploaded File:Leadglass F8 velo pmt2.jpg (plot the TOF peak position as function of the cosmic ray trigger sctintillator position and fit a line to the points. The inverse of the slope is proportional to the signal propagation velocity in the lead glass.)
- 10:42, 14 November 2007 Zihlmann (Talk | contribs) uploaded File:Lg adcR center.jpg (ADC spectrum of PMT response with the cosmic trigger sctintillators positioned at the center of the lead glass block. The fit is a landau convoluted with a gaussian. The PMT used are XP2262.)
- 13:49, 9 November 2007 Zihlmann (Talk | contribs) uploaded File:Lead glass refrac index.jpg (lead glass refractive index for type F1 and F8 as function of wavelength)
- 13:47, 9 November 2007 Zihlmann (Talk | contribs) uploaded File:Lead glass transmission.jpg (light transmission in lead glass type F1 and F8 as function of wavelength)
- 14:24, 1 November 2007 Zihlmann (Talk | contribs) uploaded File:Qe feu843.jpg (quantum efficiency for FEU-84-3 PMT)
- 16:33, 30 October 2007 Zihlmann (Talk | contribs) uploaded File:Raddam.jpg (lead glass transparency dependence on wavelength)
- 13:39, 1 October 2007 Zihlmann (Talk | contribs) moved page GlueXWiki:Help to PMT FEU-84-3
- 14:00, 10 September 2007 Zihlmann (Talk | contribs) uploaded File:Part mult vs angl 1.jpg
- 13:43, 10 September 2007 Zihlmann (Talk | contribs) uploaded File:Part mult vs angl 2b.jpg