− | ===Specification | + | ===Global Tagging Spectrometer Specification=== |
<table> | <table> | ||
<tr><td width="250">Main beam momentum</td><td> 12 GeV/c</td></tr> | <tr><td width="250">Main beam momentum</td><td> 12 GeV/c</td></tr> | ||
Line 8: | Line 8: | ||
<tr><td>Magnetic field (full excitation)</td><td> 15.0000 kG</td></tr> | <tr><td>Magnetic field (full excitation)</td><td> 15.0000 kG</td></tr> | ||
<tr><td>Pole gap</td><td> 30 mm</td></tr> | <tr><td>Pole gap</td><td> 30 mm</td></tr> | ||
+ | </table> | ||
+ | |||
+ | ===Tagger Dipoles=== | ||
+ | <table> | ||
+ | <tr><td width="80">Length 3.09 m | ||
+ | <tr><td>Width 1.09 m | ||
+ | <tr><td>Height 1.41 m | ||
+ | <tr><td>Weight | ||
+ | <tr><td>Separation between magnets �40 cm | ||
+ | <tr><td>Angle between magnets 0.892° | ||
+ | </table> |
Revision as of 18:53, 29 January 2008
Global Tagging Spectrometer Specification
Main beam momentum | 12 GeV/c |
Momenum range of analyzed electrons | 0.5 to 9 GeV/c |
Main beam radius | 26.685 m |
Main beam bending angle | 13.4° |
Entrance face angle for the first magnet | 5.9° |
Magnetic field (full excitation) | 15.0000 kG |
Pole gap | 30 mm |
Tagger Dipoles
Length 3.09 m |
Width 1.09 m |
Height 1.41 m |
Weight |
Separation between magnets �40 cm |
Angle between magnets 0.892° |