Difference between revisions of "Specification for the two-dipole tagging spectrometer"

From GlueXWiki
Jump to: navigation, search
(Specifications for tagger dipoles)
(Specification for tagger dipoles)
Line 1: Line 1:
===Specification for tagger dipoles===
+
===Global Tagging Spectrometer Specification===
 
<table>
 
<table>
 
<tr><td width="250">Main beam momentum</td><td> 12 GeV/c</td></tr>
 
<tr><td width="250">Main beam momentum</td><td> 12 GeV/c</td></tr>
Line 8: Line 8:
 
<tr><td>Magnetic field (full excitation)</td><td> 15.0000 kG</td></tr>
 
<tr><td>Magnetic field (full excitation)</td><td> 15.0000 kG</td></tr>
 
<tr><td>Pole gap</td><td> 30 mm</td></tr>
 
<tr><td>Pole gap</td><td> 30 mm</td></tr>
 +
</table>
 +
 +
===Tagger Dipoles===
 +
<table>
 +
<tr><td width="80">Length 3.09 m
 +
<tr><td>Width 1.09 m
 +
<tr><td>Height 1.41 m
 +
<tr><td>Weight
 +
<tr><td>Separation between magnets �40 cm
 +
<tr><td>Angle between magnets 0.892&deg;
 +
</table>

Revision as of 18:53, 29 January 2008

Global Tagging Spectrometer Specification

Main beam momentum 12 GeV/c
Momenum range of analyzed electrons 0.5 to 9 GeV/c
Main beam radius 26.685 m
Main beam bending angle 13.4°
Entrance face angle for the first magnet 5.9°
Magnetic field (full excitation) 15.0000 kG
Pole gap 30 mm

Tagger Dipoles

Length 3.09 m
Width 1.09 m
Height 1.41 m
Weight
Separation between magnets �40 cm
Angle between magnets 0.892°