Difference between revisions of "Specification for the two-dipole tagging spectrometer"
From GlueXWiki
(→Specification for tagger dipoles) |
(→Tagger Dipoles) |
||
Line 12: | Line 12: | ||
===Tagger Dipoles=== | ===Tagger Dipoles=== | ||
<table> | <table> | ||
− | <tr><td width=" | + | <tr><td width="120">Length</td>td>3.09 m</td></tr> |
− | <tr><td>Width 1.09 m | + | <tr><td>Width</td>td>1.09 m</td></tr> |
− | <tr><td>Height 1.41 m | + | <tr><td>Height</td>td>1.41 m</td></tr> |
− | <tr><td>Weight | + | <tr><td>Weight</td>td>38 Mg</td></tr> |
− | <tr><td>Separation between magnets | + | <tr><td>Separation between magnets</td>td>40 cm</td></tr> |
− | <tr><td>Angle between magnets 0.892° | + | <tr><td>Angle between magnets</td>td>0.892°</td></tr> |
</table> | </table> |
Revision as of 18:54, 29 January 2008
Global Tagging Spectrometer Specification
Main beam momentum | 12 GeV/c |
Momenum range of analyzed electrons | 0.5 to 9 GeV/c |
Main beam radius | 26.685 m |
Main beam bending angle | 13.4° |
Entrance face angle for the first magnet | 5.9° |
Magnetic field (full excitation) | 15.0000 kG |
Pole gap | 30 mm |
Tagger Dipoles
Length | td>3.09 m</td>