Difference between revisions of "Specification for the two-dipole tagging spectrometer"

From GlueXWiki
Jump to: navigation, search
(Tagger Dipoles)
(Tagger Dipole Coils)
Line 22: Line 22:
 
===Tagger Dipole Coils===
 
===Tagger Dipole Coils===
 
<table>
 
<table>
<tr><td width="250">Total number of ampere turns for each magnet</td><td>61560</td></tr>
+
<tr><td width="350">Total number of ampere turns for each magnet</td><td>61560</td></tr>
 
<tr><td>Copper conductor dimensions</td><td>11 x 11 mm<sup>2</sup></td></tr>
 
<tr><td>Copper conductor dimensions</td><td>11 x 11 mm<sup>2</sup></td></tr>
 
<tr><td>Copper conductor hollow core</td><td>7 mm diameter channel</td></tr>
 
<tr><td>Copper conductor hollow core</td><td>7 mm diameter channel</td></tr>
Line 36: Line 36:
 
<tr><td>Outside dimension of each coil</td><td> 92 x 152 mm<sup>2</sup>
 
<tr><td>Outside dimension of each coil</td><td> 92 x 152 mm<sup>2</sup>
 
<tr><td>Coil treatment</td><td>should be vacuum impregnated
 
<tr><td>Coil treatment</td><td>should be vacuum impregnated
 +
</table>

Revision as of 19:02, 29 January 2008

Global Tagging Spectrometer Specification

Main beam momentum 12 GeV/c
Momenum range of analyzed electrons 0.5 to 9 GeV/c
Main beam radius 26.685 m
Main beam bending angle 13.4°
Entrance face angle for the first magnet 5.9°
Magnetic field (full excitation) 15.0000 kG
Pole gap 30 mm

Tagger Dipoles

Length3.09 m
Width1.09 m
Height1.41 m
Weight38 Mg
Separation between magnets40 cm
Angle between magnets0.892°

Tagger Dipole Coils

Total number of ampere turns for each magnet61560
Copper conductor dimensions11 x 11 mm2
Copper conductor hollow core7 mm diameter channel
Conductor configuration of each coil7 x 12
Current density at nominal field4.44 A/mm2
Electrical resistance of each coil0.124
Current in conductor366.43 A
Voltage drop across 4 coils connected in series181.7 V
Total power consumption67 kW
Cooling circuits per coil7
Total flow rate for 20◦C rise80 l/min
Water supply pressure drop2.0 atm
Outside dimension of each coil 92 x 152 mm2
Coil treatmentshould be vacuum impregnated