Difference between revisions of "Specification for the two-dipole tagging spectrometer"
From GlueXWiki
Line 1: | Line 1: | ||
<table> | <table> | ||
− | <tr><td>Main beam momentum</td><td> 12 GeV/c</td></tr> | + | <tr><td width="250">Main beam momentum</td><td> 12 GeV/c</td></tr> |
<tr><td>Momenum range of analyzed electrons</td><td> 0.5 to 9 GeV/c</td></tr> | <tr><td>Momenum range of analyzed electrons</td><td> 0.5 to 9 GeV/c</td></tr> | ||
<tr><td>Main beam radius</td><td> 26.685 m</td></tr> | <tr><td>Main beam radius</td><td> 26.685 m</td></tr> |
Revision as of 18:50, 29 January 2008
Main beam momentum | 12 GeV/c |
Momenum range of analyzed electrons | 0.5 to 9 GeV/c |
Main beam radius | 26.685 m |
Main beam bending angle | 13.4° |
Entrance face angle for the first magnet | 5.9° |
Magnetic field (full excitation) | 15.0000 kG |
Pole gap | 30 mm |