Specification for the two-dipole tagging spectrometer

From GlueXWiki
Revision as of 18:53, 29 January 2008 by Jonesrt (Talk | contribs) (Specification for tagger dipoles)

Jump to: navigation, search

Global Tagging Spectrometer Specification

Main beam momentum 12 GeV/c
Momenum range of analyzed electrons 0.5 to 9 GeV/c
Main beam radius 26.685 m
Main beam bending angle 13.4°
Entrance face angle for the first magnet 5.9°
Magnetic field (full excitation) 15.0000 kG
Pole gap 30 mm

Tagger Dipoles

Length 3.09 m
Width 1.09 m
Height 1.41 m
Weight
Separation between magnets �40 cm
Angle between magnets 0.892°