Spring 2016 Trigger Summary

From GlueXWiki
Jump to: navigation, search

GTP Trigger Summary Table

Mask Condition FCAL rings masked Prescale Run Start Run End Date Range Log entry
FCAL-BCAL
0000001 10*FCAL + 3*BCAL > 18000 4 1 10347 10490 2/18/16 - 2/23/16 3383454
0000001 10*FCAL + 2*BCAL > 18000 && FCAL > 200 4 1 10491 11126 2/23/16 - 3/31/16
0000001 10*FCAL + 2*BCAL > 18000 && FCAL > 200 2 1 11127 - 3/31/16 - 3394095
FCAL
0000010 FCAL > 1800 4 1 10347 10727 2/18/16 - 3/4/16
BCAL
0000100 BCAL > 6000 N/A 1 10347 10490 2/18/16 - 2/23/16
0000100 BCAL > 9000 N/A 1 10491 10832 2/23/16 - 3/7/16 3383454
0000100 BCAL > 18000 N/A 1 10833 11126 3/7/16 - 3/31/16
0000100 BCAL > 25000 N/A 1 11127 - 3/31/16 - 3394095
PS
0001000 PSC Coincidence N/A 3 10389 11126 2/19/16 - 4/1/16 3381680
0001000 PSC Coincidence N/A 1 11127 - 4/1/16 -
FCAL-BCAL Alternate Equation
0010000 20*FCAL + 1*BCAL > 36000 && FCAL > 200 2 1 11206 - 4/8/16 - 3397302
FCAL-ST Minimum Bias
0100000 FCAL > 900 && # ST hit > 0 2 2 11206 - 4/8/16 - 3397302
ST-TAGH Minimum Bias
1000000 ST hit and TAGH hit in energy specified energy range N/A  ?  ?  ?  ?  ?

Front Panel Trigger Summary Table

FP Input FP Bit Run Start Date Start Log entry
FCAL LED 3 11333 4/12/16 3397348
BCAL LED Upstream 9 10506 2/24/16
BCAL LED Downstream 10 10506 2/24/16
Random pulser 12 11299 4/11/16 3397771

Monitoring Configuration File Changes

The configuration files (e.g. FCAL_BCAL_PS_m7.conf) are stored in RCDB for each run, and contain all the relevant configuration variables. This link: Configuration File Changes: Spring 2016 provides a list of when the standard production configuration file changed (according to RCDB), and the difference with the previous configuration file. The specific run numbers for various trigger changes in the table above are derived from these configuration files.