Difference between revisions of "Spring 2017 Trigger Summary"

From GlueXWiki
Jump to: navigation, search
(GTP Trigger Summary Table)
Line 16: Line 16:
 
| colspan="8" style="text-align: center;" | '''FCAL-BCAL'''
 
| colspan="8" style="text-align: center;" | '''FCAL-BCAL'''
 
|-
 
|-
| 0000001
+
| 000000001
| 10*FCAL + 2*BCAL > 18000 && FCAL > 200
+
| 25*FCAL + 1*BCAL > 45000 && FCAL > 200
 
| 2
 
| 2
 
| 1
 
| 1
|  
+
| 30274
|
+
| 31057
|  
+
| Full Run Period
 
|
 
|
 
|-
 
|-
 
| colspan="8" style="text-align: center;" | '''BCAL'''
 
| colspan="8" style="text-align: center;" | '''BCAL'''
 
|-
 
|-
| 0000100
+
| 000000100
| BCAL > 18000
+
| BCAL > 54000
 
| N/A
 
| N/A
 
| 1
 
| 1
Line 38: Line 38:
 
| colspan="8" style="text-align: center;" | '''PS'''
 
| colspan="8" style="text-align: center;" | '''PS'''
 
|-
 
|-
| 0001000
+
| 000001000
 
| PSC Coincidence
 
| PSC Coincidence
 
| N/A
 
| N/A
 
| 1
 
| 1
|  
+
| 30274
|  
+
| 31057
|
+
| Full Run Period
 
|  
 
|  
 
|-
 
|-
| colspan="8" style="text-align: center;" | '''FCAL-ST Minimum Bias'''
+
| colspan="8" style="text-align: center;" | '''FCAL-BCAL-ST'''
 
|-
 
|-
| 0100000
+
| 010000000
| FCAL > 900 && # ST hit > 0
+
| 25*FCAL + 1*BCAL > 45000 && FCAL > 200 && # ST hit > 0
 
| 2
 
| 2
| 2
+
| 1
|  
+
| ?
|  
+
| ?
|
+
| ?
|  
+
| ?
 
|-
 
|-
 
| colspan="8" style="text-align: center;" | '''ST-TAGH Minimum Bias'''
 
| colspan="8" style="text-align: center;" | '''ST-TAGH Minimum Bias'''
 
|-
 
|-
| 1000000
+
| 100000000
 
| ST hit and TAGH hit in energy specified energy range
 
| ST hit and TAGH hit in energy specified energy range
 
| N/A
 
| N/A
Line 82: Line 82:
 
| '''FCAL LED'''
 
| '''FCAL LED'''
 
| 3
 
| 3
| 11333
+
|  
| 4/12/16
+
|  
| [https://logbooks.jlab.org/entry/3397348 3397348]
+
|  
 
|-
 
|-
 
| '''BCAL LED Upstream'''
 
| '''BCAL LED Upstream'''
 
| 9
 
| 9
| 10506
+
|  
| 2/24/16
+
|  
 
|  
 
|  
 
|-
 
|-
 
| '''BCAL LED Downstream'''
 
| '''BCAL LED Downstream'''
 
| 10
 
| 10
| 10506
+
|  
| 2/24/16
+
|  
 
|
 
|
 
|-  
 
|-  
 
| '''Random pulser'''
 
| '''Random pulser'''
 
| 12
 
| 12
| 11299
+
|  
| 4/11/16
+
|  
| [https://logbooks.jlab.org/entry/3397771 3397771]
+
|  
 
|}
 
|}
  

Revision as of 07:45, 21 March 2017

GTP Trigger Summary Table

Mask Condition FCAL rings masked Prescale Run Start Run End Date Range Log entry
FCAL-BCAL
000000001 25*FCAL + 1*BCAL > 45000 && FCAL > 200 2 1 30274 31057 Full Run Period
BCAL
000000100 BCAL > 54000 N/A 1
PS
000001000 PSC Coincidence N/A 1 30274 31057 Full Run Period
FCAL-BCAL-ST
010000000 25*FCAL + 1*BCAL > 45000 && FCAL > 200 && # ST hit > 0 2 1  ?  ?  ?  ?
ST-TAGH Minimum Bias
100000000 ST hit and TAGH hit in energy specified energy range N/A  ?  ?  ?  ?  ?

Front Panel Trigger Summary Table

FP Input FP Bit Run Start Date Start Log entry
FCAL LED 3
BCAL LED Upstream 9
BCAL LED Downstream 10
Random pulser 12

Monitoring Configuration File Changes

The configuration files (e.g. FCAL_BCAL_PS_m9.conf) are stored in RCDB for each run, and contain all the relevant configuration variables. This link: Configuration File Changes: Spring 2017 provides a list of when the standard production configuration file changed (according to RCDB), and the difference with the previous configuration file. The specific run numbers for various trigger changes in the table above are derived from these configuration files.